00194440-10_SM_X-Series_Customer_en.pdf - 第367页

Description of the Circuit Boards 6.2.3 Head Interface C500 Gantry Service Manual SIPLACE X Series 367 6.2.3.1 6 . 2 . 3 . 1 L E D s o n t h e H e a d I n t e r f a c e LEDs on the Head Interface Head interface with stat…

100%1 / 384
Description of the Circuit Boards
Gantry 6.2.3 Head Interface C500
366 Service Manual SIPLACE X Series
6.2.3
6.2.3 Head Interface C500
Head Interface C500
Head interface (C500)
1 X16 temperature sensor for X axis 4 X13 / X14 connector for 16 Bit processor
board (TQM module)
2 Proximity switches for X axis travel range
(not with A364)
5 DIP switch
3 X15 connector for incremental encoder X
axis (X24 connector digital track signals X
axis)
6 X20/X21 both connections can be used for
the temperature sensors.
NOTICE
X4I
In SIPLACE X4I machines, a mirrored version of the C500 head interface is used on gantries
2 and 4.
Note the different item number!
Description of the Circuit Boards
6.2.3 Head Interface C500 Gantry
Service Manual SIPLACE X Series 367
6.2.3.1
6.2.3.1 LEDs on the Head Interface
LEDs on the Head Interface
Head interface with status LEDs
LED H1-H6,H17,H18 (functional check)
H17 SPI - Serial parallel interface (Test)
H6 D-ON - digital ON 5V DC/DC converter (power supply head interface, generated from the 24V)
H5 H-OK - Head adapter board connected
H4 C-In - CAN Internal (status off)
H3 MRST - Main Reset (always off)
H2 F-UC – Failure - UC test
F-UC flashes red after machine is switched on:
- eSW was unable to execute one or more functions or to initialize a subsystem.
- flashes while the production power fail signal is active or 15V missing.
H1 MP - Main Power fail, mean 5 V power supply being missing at the machine (e.g. CAN Bus)
H18 1 Wire LED shows the high level on PIN 1 of 5V ON is green --> OK
LED H7- H15, H1B (LEDs for voltages)
H14 Vcc - shows the output signal of the DC/DC converter (H6) +5 V
H13 N15V – -15 V for TwinHead --> force measurement board (not for X4I)
H15 P3.3V - Controller OK
H12 P15V - Plus +15 Volt light barrier bottom C&P head
H11 P24V - 24 V power supply (e.g.stepping motor)
H10 AV ER - Failure 5 V
H9 EN AN – 16 bit processor connected --> supply voltage OK
H8 P5V - 5 V power supply track signals X axis --> red LED ON at error
H1 B P5V – 5 V power supply for digital switching --> outside tolerance
H7 X-Temp - Temperature monitoring X axis
Description of the Circuit Boards
Gantry 6.2.3 Head Interface C500
368 Service Manual SIPLACE X Series
6.2.3.2
6.2.3.2 DIP Switches on the Head Interface
DIP Switches on the Head Interface
* Not all gantries may be available, depending on the machine type.
S Gantry* Comments
1 2 3 4
1OF
F
ON OF
F
ON P0 - Gantry address switch 1
2OF
F
OF
F
ON ON P1 - Gantry address switch 2
3ONONONONCAN R - CAN terminator (always OFF for
TwinHead)
4OF
F
OF
F
OF
F
OF
F
Boot - CAN processor 16 bit
5OF
F
OF
F
OF
F
OF
F
Reset - CAN processor 16 bit
6OF
F
OF
F
OF
F
OF
F
C0 - CAN Address switch
7OF
F
OF
F
OF
F
OF
F
C1 - CAN Address switch
8OF
F
OF
F
OF
F
OF
F
WPE - Write protect enable at the moment
OFF
CAUTION
Switch 3 (does not apply for X4I machines)
With Head Modularity pay attention: That terminating CAN resistor is set correctly:
Switch 3 is set to ON for C&P heads, to OFF for Twin heads.