Service Work Component Trolley HF R2 3.11.4 Replacing the Feeder Control Unit [03002 179] 234 Service Manua l SIPLACE X Series 3.11.4 3 . 1 1 . 4 R e p la c in g t h e F e e d e r C o n t r o l U n it [ 0 3 0 0 2 1 7 9 ]…

100%1 / 384
Service Work
3.11.3 Replacing the Table Plate [03020457-xx] Component Trolley HF R2
Service Manual SIPLACE X Series 233
Removal/installation
Thread the connection cables for the new ODU connector through the hole provided.
Reconnect the feeder control unit to the electrical system.
Reconnect the compressed air system and the ground cable.
Fasten the ODU connector with the fitting screws (1) at the top and with the fastening screws (2) at
the bottom.
3.11.3
3.11.3 Replacing the Table Plate [03020457-xx]
Replacing the Table Plate [03020457-xx]
Removal/installation
Lift the table plate out of the component trolley.
Lift the new table plate into the component trolley.
Reconnect the compressed air system and the ground cable.
Fit the table plate with the two fastening screws and the guidance rods.
Secure the two fastening screws with Loctite 243.
Loosen the top fitting screws (1) on the ODU connec-
tor.
Loosen the bottom fastening screws (2) and remove
the ODU connector.
Disconnect the connection cable from the back of the
feeder control unit.
NOTICE!
The cable for the option "Splice Detection" is already in-
tegrated into the cable tree and is run in a bundle under
the table.
Disconnect from the compressed air system.
Move the component trolley out of the machine.
Remove the waste tape container (4).
Dismantle the feeder control unit (3).
Remove the two screws (1) fastening the guide rods
to the table plate (2).
Remove the guidance rods from the height adjust-
ment system.
Unplug the ground cable and the compressed air sys-
tem from the underside of the table.
CAUTION
Heavy machine part!
The table plate is heavy (approx. 29 kg). You will need to enlist the help of a second strong
person to help you lift it out.
Service Work
Component Trolley HF R2 3.11.4 Replacing the Feeder Control Unit [03002179]
234 Service Manual SIPLACE X Series
3.11.4
3.11.4 Replacing the Feeder Control Unit [03002179]
Replacing the Feeder Control Unit [03002179]
Overview
1. Feeder control unit (FCU)
Move the component trolley out of the machine.
Unplug the connection cable from the back of the
FCU.
Loosen the fastening screws.
Fit the new FCU and reconnect to the electrical sys-
tem.
Service Work
3.12.1 Replacing the Power Pack [03025938-XX] Docking Station for X-Series Component Trolley
Service Manual SIPLACE X Series 235
3.12
3.12 Docking Station for X-Series Component Trolley
Docking Station for X-Series Component Trolley
3.12.1
3.12.1 Replacing the Power Pack [03025938-XX]
Replacing the Power Pack [03025938-XX]
Parts, equipment and tools
Circuit diagram folder for your machine
Overview
Removal/installation
Reconnect the connection leads and install the new power pack.
Connect the power pack connection cable and press the ON/OFF button to switch on.
Set the output voltage of the power pack to 26.8 V (+/- 0.5 V) at terminals nine and twelve.
Refit the cover.
1. Cover
2. Bar for clamping the cover
3. Fastening screws
4. Power pack
Loosen the four screws (3) fastening the cover (1).
The cover is clamped in place with the help of the bar
(2).
Pull the cover out of the docking station.
Take care not to damage the earth connection.
DANGER!
Switch off the voltage supply
Press the ON/OFF button (1) to switch off, and discon-
nect the power supply.
Loosen the four screws (2) fastening the power pack
(3) on the inside of the docking station.
Label the connection leads and disconnect these
from the terminal strip (4).