Service Work Modular PCB Conveyor System 3.6.16 Mapping 180 Service Manua l SIPLACE X Series 3.6.16 3 . 6 . 1 6 M a p p in g Mapping Tools and Equipment ▪ Mapping test plate HF 508x450 [003 73952-xx] For X series single …

100%1 / 384
Service Work
3.6.15 Replacing the Laser Light Barriers for Stopper Positions [00370385-xx] Modular PCB Conveyor System
Service Manual SIPLACE X Series 179
Removal/Installation of complete transmitter module
Switch the machine on.
Move the conveyor system to maximum width.
Turn the three fastening screws to align the transmitter diode centrally to the receiver. The entire
height of the laser beam must hit the receiver.
Removal /installation of receiver module
See also
5.4.5 Setting the Laser Light Barrier for the Stopper Position [➙ 331]
Loosen the two fastening screws on the large trans-
mitter module (1) and the three fastening screws on
the small transmitter module (2). Make sure you do
not lose the O-rings.
Unthread the connection cable as far as the relevant
conversion board of the conveyor edge.
Unplug the conversion board of the conveyor edge.
Rerun the connection cable accordingly and recon-
nect the conversion board on the conveyor edge to
the electrical system.
Fix the new transmitter module in the original posi-
tion.
Make sure that the three O-rings are placed on the
three fastening screws.
Loosen the two screws fastening the receiver module
(1).
Unthread the connection cable as far as the relevant
conversion board of the conveyor edge.
Unplug the conversion board of the conveyor edge.
Rerun the connection cable accordingly and recon-
nect the conversion board of the conveyor edge to
the electricity supply.
Fit the new receiver module in the original position.
Switch the machine on.
Move the conveyor system to maximum width.
Turn the two fastening screws to align the receiver
centrally to the transmitter diode. The entire height of
the transmitter diode laser beam must hit the receiv-
er.
Service Work
Modular PCB Conveyor System 3.6.16 Mapping
180 Service Manual SIPLACE X Series
3.6.16
3.6.16 Mapping
Mapping
Tools and Equipment
Mapping test plate HF 508x450 [00373952-xx]
For X series single conveyor 450x508 mm, for dual conveyor rotated by 90°
Mapping test plate 520x300 set [03076124-xx]
This special mapping plate was designed with a width of 300 mm for the quad lane machines. These
machines can only be mapped with this mapping plate, as the conveyor can not be set to a width of
450 mm.
Performing mapping
Start SITEST.
Start the overall reference run.
NOTICE
Use the calibration tool [03034148-xx] for the C&P20.
For all other placement heads and the glass mapping plate, use the new calibration tool version
3 [03010565-xx]. This applies for HF, X and D series machines plus for PCB mapping and com-
ponent mapping.
NOTICE
SW70x
The procedure for the SW70x is identical.
Go to mode Calibrate machine and select Ad-
vanced... for advanced PCB mapping.
Select the processing areas and the mapping func-
tions (jobs).
Service Work
3.6.16 Mapping Modular PCB Conveyor System
Service Manual SIPLACE X Series 181
Select the Conveyor .
Select the Mapping plate width as 300 mm.
If you only have one mapping plate available, select
Process jobs in PA1 first and then in PA2.
If you have two mapping plates available, select Pro-
cess jobs in parallel in both processing areas.
Start the mapping procedure.
You will now be asked to prepare the placement are-
as.