00194440-10_SM_X-Series_Customer_en.pdf - 第379页
Description of the Circuit Boards 6.6.1 NC main board CPx [03069324-xx] Nozzle Changers Service Manual SIPLACE X Series 379 6.6 6 . 6 N o z z le C h a n g e r s Nozzle Changers 6.6.1 6 . 6 . 1 N C m a in b o a r d C P x …

Description of the Circuit Boards
COT insert 6.5.1 Connecting assy FCU [03059783-xx]
378 Service Manual SIPLACE X Series
6.5
6.5 COT insert
COT insert
6.5.1
6.5.1 Connecting assy FCU [03059783-xx]
Connecting assy FCU [03059783-xx]
03059783-04
LED (test mode for reject box switched off – S2.1 ON) [03059783-04]
LED (test mode for reject box switched on – S2.1 OFF) [03059783-04]
Button S1 [03059783-04]
Dip switch S2 [03059783-04]
LED Color Status Signal name Description
H1, H2, H3, H4 GN Sequential shift
light
LED1, 2, 3, 4 FCU OK
H1, H2, H3, H4 GN ON LED1, 2, 3, 4 eSW application missing
H1, H2, H3, H4 GN Flashing LED1, 2, 3, 4 FCU error, reboot place-
ment machine or replace
FCU
LED Color Status Signal name Description
H1 or H2 or H3 or
H4
GN Flashes LED1 or 2 or 3 or
4
No sensor connected for
reject box 1 or 2 or 3 or 4
H1 or H2 or H3 or
H4
GN OFF LED1 or 2 or 3 or
4
Sensor for reject boxes 1 or
2 or 3 or 4 connected, but
no reject box inserted
H1 or H2 or H3 or
H4
GN ON LED1 or 2 or 3 or
4
Sensor for reject boxes 1 or
2 or 3 or 4 connected, but
no reject box inserted
Buttons Status Function Description
S1 OFF RESET When pressed
Switch Status Signal name Description
S2.1 ON/OFF FCU_ENV3 ON: test mode for reject box switched off
OFF: test mode for reject box switched on
S2.2 OFF FCU_ENV2 40-fold FCU
S2.3 ON/OFF FCU_ENV1 ON: without insert control, with virtual button
OFF: with insert control, without virtual button
S2.4 ON/OFF FCU_ENV0 ON: with tape cutter and with nozzle changer
functionality
OFF: without tape cutter and without nozzle
changer functionality

Description of the Circuit Boards
6.6.1 NC main board CPx [03069324-xx] Nozzle Changers
Service Manual SIPLACE X Series 379
6.6
6.6 Nozzle Changers
Nozzle Changers
6.6.1
6.6.1 NC main board CPx [03069324-xx]
NC main board CPx [03069324-xx]
03069324-02
LED [03069324-02]
LED Color Status Signal name Description
H1 GN ON LED_Magazines_OK Magazines inserted properly
H2 GN ON LED_LB_OPENED Actuator light barrier "open"
H3 GN ON LED_LB_CLOSED Actuator light barrier "closed"
H4 GN ON LED_FPGA_OK FPGA has been loaded and is ready for op-
eration
H5 GN ON SWITCH_VALVE Valve voltage of +24V present
H6 GN ON P3V3 Logic voltage +3.3V present
H7 RD ON FPGA_TEST_6 Internal FPGA status 1
H8 RD ON FPGA_TEST_2 Internal FPGA status 2
H9 RD ON FPGA_TEST_4 Internal FPGA status 3
H10 RD ON FPGA_TEST_1 Internal FPGA status 4
H11 RD ON FPGA_TEST_3 Internal FPGA status 5
H12 RD ON FPGA_TEST_5 Internal FPGA status 6

Description of the Circuit Boards
Nozzle Changers 6.6.2 Nozzle Changer Main Board C&P20P [03107652-xx]
380 Service Manual SIPLACE X Series
6.6.2
6.6.2 Nozzle Changer Main Board C&P20P [03107652-xx]
Nozzle Changer Main Board C&P20P [03107652-xx]
Nozzle Changer CP20P - Jumper X10
Jumper X10
Head Jumper position
SW <= 706.x SW >= 707.x
CPx, DLM 1-2 1-2 or 2-3
C&P20 P --- 2-3 (factory settings)