Service Work 3.6.22 Overview of the Electr ical Components Modular PCB Conveyo r System Service Manual SIPLACE X Series 191 Installation See also 5.4.7 Read justing the H older for the Stopper and Proximity Swit ch (…

Service Work
Modular PCB Conveyor System 3.6.21 Replacing and Setting the Stopper (QC) [03069271-xx]
190 Service Manual SIPLACE X Series
Removal
Basic stopper unit for quad lane [03069271-xx]
1. Stroke limitation rail
2. Stop rail
3. Sensor lower end position stopper [03066803-xx]
4. Stopper bolt
Stopper unit with sonar sensor in the placement area
CAUTION!
Dismantling is only possible if a setting gauge was used
for adjustment.
► Move the conveyor to a suitable position in which you
can easily access the stopper (1) . You may need to
undock the relevant component trolley.
► Loosen all electrical and pneumatic connections to
the stopper.
► Loosen the two screws (2) fastened with locking var-
nish and remove the stopper.

Service Work
3.6.22 Overview of the Electrical Components Modular PCB Conveyor System
Service Manual SIPLACE X Series 191
Installation
See also
5.4.7 Readjusting the Holder for the Stopper and Proximity Switch (QC) [ ➙ 338]
3.6.22
3.6.22 Overview of the Electrical Components
Overview of the Electrical Components
3.6.22.1
3.6.22.1 Conveyor Edge Conversion Board [00359424-xx]
Conveyor Edge Conversion Board [00359424-xx]
Overview
► Fit the new stopper.
► Restore all electrical and pneumatic connections.
CAUTION!
If you have loosened or removed the holding fixture (1)
for the stopper and proximity switch during work, this will
need to be readjusted.
1. Conveyor edge conversion board
2. Cover
The conversion boards for the conveyor edges (1) are sit-
uated on the respective conveyor edges, under a cover
(2).
For terminal assignment details, please refer to the cur-
rent version of the circuit diagram folder.
1
2

Service Work
Modular PCB Conveyor System 3.6.22 Overview of the Electrical Components
192 Service Manual SIPLACE X Series
3.6.22.2
3.6.22.2 Conveyor Conversion Board (Single and Dual Conveyor) [00359425-xx]
Conveyor Conversion Board (Single and Dual Conveyor) [00359425-xx]
Overview
3.6.22.3
3.6.22.3 Conveyor Conversion Board (Quad Lane Conveyor) [03066716-xx]
Conveyor Conversion Board (Quad Lane Conveyor) [03066716-xx]
See also
3.6.17 Replacing the Conveyor Conversion Board [ ➙ 183]
1. Conveyor conversion board
2. Cover
The conveyor conversion board (1) is situated in the vi-
cinity of the intermediate conveyor, under the cover (2).
For terminal assignment details, please refer to the cur-
rent version of the circuit diagram folder.
1
2
Connection assignment for the assembly tub conversion
board
1. Conveyor conversion board
2. Cover
This board is located in the intermediate conveyor under
a cover.
For terminal assignment details, please refer to the cur-
rent version of the circuit diagram folder.