00194440-10_SM_X-Series_Customer_en.pdf - 第348页
Settings Settings on the Component Trolley 5.5.2 Component T rolley - Sett ing the Basic Height 348 Service Manua l SIPLACE X Series 5.5.2.2 5 . 5 . 2 . 2 A d ju s t in g t h e C o m p o n e n t T r o lle y t o t h e B o…

Settings
5.5.1 Setting the Actuator on the Component Trolley Settings on the Component Trolley
Service Manual SIPLACE X Series 347
5.5
5.5 Settings on the Component Trolley
Settings on the Component Trolley
5.5.1
5.5.1 Setting the Actuator on the Component Trolley
Setting the Actuator on the Component Trolley
Parts, equipment and tools
▪ Allen key
Setting
See also
3.10.6 Replacing the Actuator/Protective Bracket [ ➙ 231]
5.5.2
5.5.2 Component Trolley - Setting the Basic Height
Component Trolley - Setting the Basic Height
5.5.2.1
5.5.2.1 Parts, equipment and tools
Parts, equipment and tools
The following tools and equipment are needed to adjust the height of the component trolley:
▪ Set of Allen keys, size 5
▪ Eyebolt with M12 thread to raise the component trolley table,
DIN 580 M12-St [00048350-xx]
▪ Leverage device for raising the component trolley table, must be able to carry at least 80 kg
► Set the actuator with the help of the grub screw (3).
Between the upper edge (1) of the table and the
actuator (2) you need to set an angle of 13° +/- 1°.
The actuator must be able to slide into the safety
switch without rubbing against the plastic.

Settings
Settings on the Component Trolley 5.5.2 Component Trolley - Setting the Basic Height
348 Service Manual SIPLACE X Series
5.5.2.2
5.5.2.2 Adjusting the Component Trolley to the Board Transport Height
Adjusting the Component Trolley to the Board Transport Height
Component trolley with a PCB conveyor height of
950 mm
▪ Holes drilled for board transport heights 830 -
950 mm in the guidance bars
The component trolley for the S feeder modules can be
easily and quickly adjusted to the following board trans-
port heights:
▪ 830 mm ±15 mm standard height
▪ 900 mm ±15 mm SMEMA height
▪ 930 mm ± 15 mm SMEMA height
▪ 950 mm ±15 mm SMEMA height
WARNING!
The component trolley height may only be set by
SIPLACE technicians or other qualified and officially au-
thorized (certified) personnel.
Observe the applicable accident prevention regulations.
Remove all feeder modules from the changeover table
plate, before you adjust the height of the changeover ta-
ble.

Settings
5.5.2 Component Trolley - Setting the Basic Height Settings on the Component Trolley
Service Manual SIPLACE X Series 349
5.5.2.3
5.5.2.3 Adjusting the Component Trolley Height
Adjusting the Component Trolley Height
Overview
Setting
► Remove all the feeder modules from the component trolley.
► Screw the eyebolt into the M12 hole provided (1) on the component trolley table.
► Hook the leverage device into the eyebolt (2).
► Tighten the rope of the leverage device.
► Loosen the 8 hexagon socket-head screws, M6x12 (4).
► Lift or lower the component trolley table to the required height. Make sure that the hole for the re-
quired height in the bridge (5) is level with the top hole in the vertical profile bar (3).
► Fasten the bridge (5) to the vertical profile bar (3) with the eight hexagon socket-head screws M6x12
(4).
► Unscrew the eyebolt from the component trolley table.
Position of eyebolt on component trolley
1. M12 hole drilled for eyebolt
2. Eyebolt DIN 580 M12-St
3. Vertical profile bar
4. Eight pieces hexagon socket-head screw SN 62355,
M6x12
5. Bridge
CAUTION!
Always use the fit-up aid (screwed eyelet) to fix the table
plate, irrespective of whether you want to raise or lower
the component trolley.