4-15 4  aily operation 7. Setting up the mask and squeegee This section explains procedures for clamping the mask (stencil) you have prepared on the printing table and installing the squeegee onto the squeegee head. 1 O…

100%1 / 280
4-14
4
aily operation
6.3 Long-term storage tasks
If the solvent pump is not used for extended periods (about 6 months or more), then it may dry out internally
and cause operating defects. The solvent path within the pump must be blocked to prevent this from happening.
The path blocking procedure is described below.
n
Blocking the solvent path
1
Remove the cleaner cover.
1. Loosen the two screws (enclosed by a
dashed line circle in the figure on the
right) clamping the rear side of the
cleaner cover. (No need to remove
them)
2. Next remove the screws at 4 locations on
the near side (see drawing).
3. Raise the cover upward and then pull
toward you to remove it.
63413-N3-00
2
Remove the joints.
Remove the joints from two locations, one
on the head side and the other on the tank
side from the shut-off valve joint. Use caution
because alcohol remaining in the hose will
come out when the joint on the head side is
removed.
1. Remove the head side joint in the bent
state as shown by the dashed line in the
figure on the right.
2. Prepare a container, free the bent
location and let the alcohol drain into
the container.
3. Remove the tank side joint and then
quickly point it upward to let the alcohol
in the hose return back to the tank.
63414-N3-00
3
Mark the hoses you removed.
Mark the two hose sections you removed in
step 2 by winding yellow ribbon or a similar
item around them.
63415-N3-00
4
Reattach the cleaner cover.
Reinstall the cleaner cover in the reverse of
the procedure that you removed it in step 1.
Place a ribbon on the outer side of the
cover so that others will know that the joints
were removed.
n
Resetting operation
Connect the hoses in the reverse of the "Blocking the
solvent path" procedure and refill with solvent by
referring to 6.2 "Refilling the solvent". When finished
refilling, operate the solvent pump to make sure it
operates correctly.
Removing the cleaner cover
Step 1
First loosen these two screws.
Removing the joints
Step 2
Joint (to head)
Shut-off valve joint
Container
Joint (to tank)
Hose markings
Step 3
Marking (yellow ribbon, etc.) Marking
As seen from outside the cover
4-15
4
aily operation
7. Setting up the mask and squeegee
This section explains procedures for clamping the mask (stencil) you have prepared on the printing table and
installing the squeegee onto the squeegee head.
1
On the Setup screen, open the [Setup] tab under “Utility”.
The buttons on this screen are used in the following steps to change the mask and squeegee setup.
Setup screen
[Setup] tab
64425-N3-10
2
Press the [SW. Prod. Position] button and select “Mask Setup”.
n
NOTE
When both lanes are used for production, the dialog box for selecting the lane number appears, so select the lane.
The lane currently used in production is grayed out.
Dialog box for move table to setup position
64426-N3-00
4-16
4
aily operation
3
When the DOOR LOCK lamp turns off, open the safety cover.
4
Check or change the mask stopper pin position.
If you are using a mask whose frame size is different from the mask previously used, you must change
the mask stopper pin position on the left side of the printing table (W and L). Screw the mask stopper pin
into the correct hole by referring to the diagram affixed to the side of the mask stage or Appendix 7.1,
"Mask size and mask stopper pin position" in this chapter.
Mask stopper pin
L direction
Mask stopper pin
Put it here when do not
use the mask stopper pin.
63416-N3-00
5
Bring the mask in contact with the stopper.
While keeping the mask frame horizontal, fully insert it in against the left stopper pins along the rear
stopper pins on the printing table.
Mask frame setup
Mask clamp
Mask frame
63417-N3-00
6
Clamp the mask.
With the mask kept in contact with the left corner on the rear of the printing table, turn the mask clamp
switch located on the right of the machine clockwise to clamp the mask.
c

