YSP20_Users_E.pdf - 第69页

2-8 2  asic operations Code Error name and description Ea8548 PLEASE CHECK FOR ANY ILLEGAL RUNNING CONDITION State Operating condition settings are not suitable for production. Check followings. If all OK, please contin…

100%1 / 280
2-7
2
asic operations
n
Air-conditioner related errors
Code Error name and description
Ea8086
AIR-CONDITIONER TEMPERATURE INTERLOCK
State
Temperature in the machine is not suitable for production.
You cannot run the machine under this condition.
Cause
Please check Air-Conditioner.
1. Power supply off of Air-Conditioner
2. Air-Conditioner is not effective.
Action
Ea8087
AIR-CONDITIONER WATER FULL
State The water tank of Air-Conditioner is full.
Cause
Action
Ea8094
AIR-CONDITIONER INTERLOCK
State The Air-conditioner doesn't work normally.
Cause
Please check Air-Conditioner.
1. The Air-Conditioner broke down.
2. Ten minutes passed after the water tank of Air-Conditioner is full.
Action
n
Data check errors
Code Error name and description
Ea0452
DATA CHECK ERROR
State Current Board data has some data error.
Cause Current Board data has some data error.
Action Please read same Board data, and correct wrong data.
Ea8507
DATA CHECK ERROR
State Squeegee speed is out of range.
Cause Squeegee speed is out of range.
Action
Please specify correct speed as follows
• Double Squeegee : 1 to 200[mm/sec]
• Enclosed Head : 1 to 100[mm/sec]
Ea8508
DATA CHECK ERROR
State Print pressure is out of range.
Cause Print pressure is out of range.
Action Please specify correct pressure from 0.01 to 200[N].
Ea8513
DATA CHECK ERROR
State Detach speed is out of range. (0.1 to 20.0mm/sec).
Cause Detach speed is out of range. (0.1 to 20.0mm/sec).
Action
Ea8537
DATA CHECK ERROR
State Illegal mask size is specified.
Cause The size is not available in this machine.
Action
2-8
2
asic operations
Code Error name and description
Ea8548
PLEASE CHECK FOR ANY ILLEGAL RUNNING CONDITION
State
Operating condition settings are not suitable for production.
Check followings. If all OK, please continue.
Cause Operating condition settings are not suitable for production.
Action
Alignment should be [UseAlign].
PrintFeedback should be [Use].
Board Inspection JudgeMode should be [Normal Judge] or [Normal Judge & Exit Judge].
Ea8599
DATA CHECK ERROR
State
In 'Controlled in the Board' cleaning, each auto cleaning interval and manual cleaning interval
must satisfy
following magnitude relation.
Cause
In 'Controlled in the Board' cleaning, each auto cleaning interval and manual cleaning interval
must satisfy
following magnitude relation.
Action
Dry Auto Interval
< Wet Auto Interval
< 'Controlled in the Board 1' Detail Auto Interval
< 'Controlled in the Board 2' Detail Auto Interval
< 'Controlled in the Board 3' Detail Auto Interval
< 'Controlled in the Board 4' Detail Auto Interval
< Manual Interval
Ea8812
DATA CHECK ERROR
State The set board size Y is over the maximum board size Y of the mask.
Cause The set board size Y is over the maximum board size Y of the mask.
Action Please change the correct board size Y or set the correct size of the mask.
Ea8815
DATA CHECK ERROR
State
Although the board may be carried out to lane 2, the set board size Y is over the maximum board size Y that
can be carried out to lane 2.
Cause The size of boards to be unloaded to Lane 2 exceeds the maximum board size that can be transported.
Action Please change the correct board size Y or set the "Lane 1" to the "Carry out Lane Setting".
2-9
2
asic operations
2. Starting and stopping the machine
This section explains routine procedures for starting and turning off the machine according to the flow charts
below.
Starting and turning off the machine
Program is loaded.
Return-to-origin dialog box appears.
Operation and production
Confirmation dialog box appears.
Move-to-origin dialog box appears.
Setup screen appears.
Return axes to origins
Turn on power switch
Check before operation
Perform return-to-origin
Press [Off] button on operation screen
Press emergency stop button
Turn off power switch switch
Specify operator
Starting the
machine
Turning off the
machine
63203-N3-00