YSP20_Users_E.pdf - 第42页

1-3 1 Part names and functions YSP20 main unit As viewed from rear of RL (right-to-left flow) machine Cleaner vaccum pressure gauge Main pressure gauge (1) Main air pressure regulator (1) Main pressure gauge (2) Main air…

100%1 / 280
1-2
1
Part names and functions
n
Signal light
Indicates current operating conditions of the mounter with a green, yellow and red light, or green, white and blue light
explained below. (The colors of the signal light can be selected from two patterns.)
Machine status Example Green
Red/
White
Yellow/
Blue
Warm-up or automatic operation ON ----- -----
Emergency stopor safety cover
switch activated
----- ON -----
System error
(with buzzer ON)
• Excessive current
• Secondary limit is exceeded
----- ON -----
Operation or board data error
(with buzzer ON)
• Error stop
• Stopped by interlock device
----- ----- ON
Materials cannot be used. Solder ----- ----- ON
Alarm buzzer
This buzzer sounds if an error or abnormal operation occurs. (The color of the signal light when a buzzer sounds can be
selected from two patterns (option). (The buzzer volume can be adjusted by turning the buzzer ring right or left.)
Safety cover
Opening this cover enters a state that allows non-stop changeover. Before opening this cover to change the mask (stencil),
squeegees, or solder type, make sure the DOOR LOCK lamp is OFF. Keep this cover closed during operation.
Edge clamp pressure gauge
Shows the air pressure for the edge clamp.
Printing section
Consists of a printing table and a squeegee head. See "3. Printing section" later in this chapter for more details.
Front panel
This panel contains the vision camera unit and conveyor unit. See "4. Conveyor unit" and "6. Vision camera unit" later in
this chapter for more details.
Cleaning unit and solvent tank (behind front and rear panelsr)
The cleaning unit uses a gauze roll to wipe away solder adhering to the mask apertures and solder coming out of the
backside of the mask while vacuuming. See "5. Cleaning unit" later in this chapter for more details.
Front lower left panel
The servo controller is located behind this panel. Keep this panel closed during operation.
Front lower right panel
Power connection terminals, transformer, and breaker are located behind this panel. Keep this panel closed during
operation.
Power switch
Turns the power to the machine on and off. The power is on when turned to the right.
c

Wait about 2 seconds before turning the Power switch back on after having turned it off.
Work instruction light
Lights up yellow to indicate the location (front or rear) where an error occurred or any material needs to be replenished.
Conveyor unit
The conveyor unit is located under the printing table. For details, see "4. Conveyor unit" in this chapter.
1-3
1
Part names and functions
YSP20 main unit
As viewed from rear of RL (right-to-left flow) machine
Cleaner vaccum
pressure gauge
Main pressure gauge (1)Main air pressure regulator (1)
Main pressure gauge (2)Main air pressure regulator (2)
USB port
Rear lower right panel
Rear lower left panel
Air supply/shut-off switch
Setup cover
Edge clamp
pressure gauge
Previous Interface (Lane 2)
Previous Interface (Lane 1)
Next Interface (Lane 2)
Next Interface (Lane 1)
63102-N3-00
1-4
1
Part names and functions
Setup cover
Opening this cover enters a state that allows non-stop changeover. Before opening this cover to change the matrix plate
or backup pins, make sure the DOOR LOCK lamp is OFF. Keep this cover closed during operation.
Pressure gauge, pressure regulator, air supply/shut-off switch
Indicates and adjusts the air pressure supplied to the machine. For details, see Appendix 1.1, "Air regulator unit".
USB port
· Machine for right-to-left flow: USB port is located on the rear left side.
· Machine for left-to-right flow: USB port is located on the front left side.
Connect to this port when using a USB memory to back up board data stored in the machine. Always close this panel
before operating a USB memory after inserting it into the port.
Cleaner negative pressure gauge
Shows the negative pressure for the cleaner.
Rear lower right panel
The machine-to-machine interface connector (labeled “NEXT”), servo controller, I/O board, and relay panel are located
behind this panel. Keep this panel closed during operation.
Rear lower left panel
The machine-to-machine interface connector (labeled “PREVIOUS”) and blower unit (blower motor and inverter) are
located behind this panel. Keep this panel closed during operation.
n
NOTE
For details on the machine-to-machine interface connectors, see Appendix 1.3, “Connection between machines”.