YSP20_Users_E.pdf - 第67页
2-6 2 asic operations Code Error name and description Ea8823 BOARD TRANSFER TIMEOUT State Failed to transfer a board from the exit to the next machine. Cause Board can stay between the lower conveyor and the entrance o…

2-5
2
asic operations
Code Error name and description
Ea29642
FIX UNIT BRAKE INTERLOCK
State Cannot verify condition of the fix unit brakes.
Cause
Cannot verify condition of the fix unit brakes. If the XY axis is moved, there is a possibility that the fixed state
of the board might be released.
Action Check the condition of the fix unit brakes.
n
Emergency stop related errors
Code Error name and description
Es521
Es00521:INTERFERE SAFETY SENSOR ERROR
State The interference safety sensor between the relevant axes is detected.
Cause The interference safety sensor between the relevant axes is detected.
Action Move the relevant axis to the position where these axes don't interfere.
Es522
Es00522:CONTACTOR ERROR
State
Has detected a mismatch of the states of the safety relay and the contactor.
The contactor may have welded.
Because the servo may not be off even when opening the machine cover, the axes can move.
Please turn off the main switch now.
Cause
• Welding of the contactor
• Poor connection of harness from the safety relay to I/O board
• Failure of the I/O board
Action
• Check the contactor
• Check the harness
• Check the I/O board
Es523
Es00523:SAFETY RELAY ERROR
State Has detected a mismatch of the states of the safety relay and the contactor.
Cause
• Failure of the contactor
• Poor connection of harness from the contactor to I/O board
• Failure of the I/O board
• Failure of the safety relay
Action
• Check the LED of safety relay
• Check the contactor
• Check the harness
• Replacing the I/O board
• Exchange of safety relay
n
Transfer related errors
Code Error name and description
Ea8820
BOARD TRANSFER TIMEOUT ERROR
State Failed to load the board from previous machine to upper conveyor.
Cause
There is possibility that the board exists on the upper conveyor, or on the exit of the previous machine's
conveyor.
Action Please check the upper conveyor and remove the board.
Ea8821
BOARD TRANSFER TIMEOUT ERROR
State Failed to load the board from wait position to print position.
Cause There is possibility that the board exists on the upper conveyor, or main conveyor.
Action Please check the upper conveyor and the main conveyor.
Ea8822
BOARD TRANSFER TIMEOUT
State Failed to transfer a board from the printing position to the exit.
Cause Board can stay between the main conveyor and the lower conveyor.
Action

2-6
2
asic operations
Code Error name and description
Ea8823
BOARD TRANSFER TIMEOUT
State Failed to transfer a board from the exit to the next machine.
Cause Board can stay between the lower conveyor and the entrance of the next machine.
Action Please remove the board.
Ea8849
Unknown board is detected at the wait position sensor
State Unknown board is detected at the wait position sensor.
Cause Unknown board is detected at the wait position sensor.
Action
1. If you supply the board to print now, please push [Unit] - [Conveyor] - [Convey In].
2. If you supply the printed board, please push [Setup] - [Setup] - [Print Board Convey Out] after remove the
board.
n
Mark related errors
Code Error name and description
Ea0256
Base-MACS Mark Detection Error
State Failed to detect Base-MACS mark.
Cause Check Base-MACS marker condition, and clean up the marker surface.
Action
Check Base-MACS marker condition, and clean up the marker surface.
To invalidate Base-MACS Function, please change the following item. [Machine Data]-[Machine Information]-
[Installation Setting]-[Base MACS]-[Not Use]
n
Cleaner unit related errors
Code Error name and description
Ea8095
CLEANING SOLVENT OUTPUT ERROR
State
Something is wrong in the output of the cleaning solvent.
Please release the EMERGENCY STOP,press [Fuel Pump] on [Unit/Cleaner] screen, and confirm whether the
cleaning solvent is correctly output.
When the cleaning solvent is not correctly output, the following causes are thought.
Cause
• Breakdown of relay of solvent pump.
• Abnormality of conveyer I/O board.
• Disconnection of I/O communication line.
Action
• Exchange of relay of solvent pump.
• Exchange of conveyer I/O boards.
• Please confirm disconnection of I/O harness,coming off of connector cable,and loosening of earth cable.
Ea8280
GAUZE ROLLING FINISHED
State All gauze has been rolled up.
Cause
Action Please exchange gauze roll for a new one.
Ea8288
CLEANER VACUUM UP CHECK ERROR
State The vacuum of the cleaner was not up when the cleaner head goes up.
Cause
1. The cleaner hose has damage.
2. The cleaner filter is choked up.
3. The exhaust valve is broken.
4. The blower motor is broken.
Action
Ea8289
CLEANER VACUUM DOWN CHECK ERROR
State The vacuum of the cleaner was not down when the cleaner head goes down.
Cause 1. The exhaust valve is broken.
Action

2-7
2
asic operations
n
Air-conditioner related errors
Code Error name and description
Ea8086
AIR-CONDITIONER TEMPERATURE INTERLOCK
State
Temperature in the machine is not suitable for production.
You cannot run the machine under this condition.
Cause
Please check Air-Conditioner.
1. Power supply off of Air-Conditioner
2. Air-Conditioner is not effective.
Action
Ea8087
AIR-CONDITIONER WATER FULL
State The water tank of Air-Conditioner is full.
Cause
Action
Ea8094
AIR-CONDITIONER INTERLOCK
State The Air-conditioner doesn't work normally.
Cause
Please check Air-Conditioner.
1. The Air-Conditioner broke down.
2. Ten minutes passed after the water tank of Air-Conditioner is full.
Action
n
Data check errors
Code Error name and description
Ea0452
DATA CHECK ERROR
State Current Board data has some data error.
Cause Current Board data has some data error.
Action Please read same Board data, and correct wrong data.
Ea8507
DATA CHECK ERROR
State Squeegee speed is out of range.
Cause Squeegee speed is out of range.
Action
Please specify correct speed as follows
• Double Squeegee : 1 to 200[mm/sec]
• Enclosed Head : 1 to 100[mm/sec]
Ea8508
DATA CHECK ERROR
State Print pressure is out of range.
Cause Print pressure is out of range.
Action Please specify correct pressure from 0.01 to 200[N].
Ea8513
DATA CHECK ERROR
State Detach speed is out of range. (0.1 to 20.0mm/sec).
Cause Detach speed is out of range. (0.1 to 20.0mm/sec).
Action
Ea8537
DATA CHECK ERROR
State Illegal mask size is specified.
Cause The size is not available in this machine.
Action