TR7500_Series_Software_v29_En.pdf - 第102页
Test Research Inc. 80 TR7500 Series User Guide – Software v.2.9.0 [Delete] - Selec t a com ponent on the co m ponent list f irst and press [Delete] to delete it. [View ] - Select a compo nent at component list f irst…

Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 79
Result:
The component,
that has enough similarity,
will be set.
You can modify
the name or angle.
Figure 136: Non-CAD Teach Procedure 3
(6) [Name & Type Setting] - Set [Name Index], [S/N From] and [Type] here for a new
component.
(7) [CAD File] - Use [New], [Load] or [Save] an AOI file. [New] creates a new AOI file and
the current setting will be cleared. [Load] opens a saved AOI file. [Save] means to save
the current AOI file to a specific path.
(8) [CAD Data] - The component data will be listed in the field. Edit the CAD data here.
[Add] - Press the button and the system will create a component into CAD file
according to [Name&Type Setting], [TB Select], [Theta] and the selecting tool.
[Modify] - Select a component first and press [Modify] then the system will change
the data according to [Name&Type Setting], [TB Select], [Theta] and the selecting
tool.
[Insert] - Select a position to insert component data in the component list first and
press the button to add a component according to [Name&Type Setting], [TB
Select], [Theta] and the selecting tool..

Test Research Inc.
80 TR7500 Series User Guide –Software v.2.9.0
[Delete] - Select a component on the component list first and press [Delete] to
delete it.
[View] - Select a component at component list first and press [View] . Then the
camera will move to the location of the component.
[TB Select] - Select whether the component is on top or bottom side.
[Arrowhead button] - Select a component first, then press up or down arrow to
move its sequence.
[CAD table] - Double click on a field and edit data directly.
Figure 137: Theta Data Field
(9) [Theta] - A tool to define the angle of components.
When using the box tool to create a component, check [Apply] and select an angle to add
[Theta] data at one time. If [Apply] is not checked, the default of [Theta] is zero.

Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 81
Figure 138: Set Theta Data When Using Box Tool
Select a [Theta] field and select an angle to change the data directly.
Figure 139: Edit Theta Angle Directly