Test Research Inc. TR7500 Series User Guide – Software v.2.9.0 295 13 A UTO -C ONVEY OR W IDTH This procedure re q uires the auto conv eyor width module. 13.1 Hardware 1. Open the auto convey or adjustment function on th…

100%1 / 330
Test Research Inc.
294 TR7500 Series User Guide –Software v.2.9.0
Component name, (Type), Defect kind [Parameter, inspected score/tolerance]
Display
Inspection box name, Defect kind, [Parameter, inspected core/tolerance]
Figure 486: Example: Defect Tree
[Reset Yield Count] – Reset the [Yield Statistic] field.
[Disable Yield Count] – Do not display the [Yield Statistic] field.
[Disable Fail Count] – Do not display the [Fail Statistic] field.
Figure 487: Results Screen with Yield & Fail Statistics Hidden
[Reset Fail Count] – Reset the [Fail Statistic] field.
[Close&Stop] – Close the window.
Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 295
13 A
UTO
-C
ONVEYOR
W
IDTH
This procedure requires the auto conveyor width module.
13.1 Hardware
1. Open the auto conveyor adjustment function on the HCI (refer to TR7500 User Guide –
Hardware).
2. Referring to the figure below, press [AUTO] then the conveyor will go to the original
position. Then press [UP] or [DOWN] to enlarge or reduce the conveyor width. When
finished, press [Enter] to save the data. Then press [Back] to go back to the stand-by
image.
Figure 488: Use HCI to Set Conveyor Width
13.2 Software Setting
1. The Windows version of the PC must be compatible with the auto conveyor width system.
2. In the Windows Registry, add a DWORD [AutoConveyorWidth] with the value = [1]
13.3 Saving Width Data to Project
1. Adjust the conveyor width with [Auto Conveyor] Function.
2. When saving the project, the system saves the width to the project automatically.
3. If the current width is not the same with the width in project, system shows the dialog
below asking to replace the saved width with current width.
Test Research Inc.
296 TR7500 Series User Guide –Software v.2.9.0
Figure 489: Confirm Save Conveyor Width
13.4 Width Loading
1. When opening a existing project, the system shows the dialog below asking to use the
saved width.
Figure 490: Confirm Auto-Set Conveyor Width
2. When select [Yes], the system starts to adjust the conveyor width; If there is a board on
the conveyor, remove the board first. If [No] is selected, the system does not perform any
action.
3. If no data was saved in the project before, none of the above requests will be made.