Test Research Inc. TR7500 Series User Guide – Software v.2.9.0 67 3.4.4 Auto Pass Level 3.4.4.1 Inline Data Coll ection Select to start the da t a collection and the data collectio n can be the basis o f auto pass level …

Test Research Inc.
66 TR7500 Series User Guide –Software v.2.9.0
3.4.3.2 By Component Name
Choosing this item displays the component list window. The window lists all pass levels and
inspection results for every component. 0 means the component does not have that kind of
inspection box. Double click on the object component to change the parameters. Check or
uncheck the square item to test or untest the component.
Figure 117: Component List Window
Figure 118: Model Image Pass Levels

Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 67
3.4.4 Auto Pass Level
3.4.4.1 Inline Data Collection
Select to start the data collection and the data collection can be the basis of auto pass level.
The system saves the most recent 30 data values and only the passed value will be
calculated.
Figure 119: Program –Auto Pass Level
3.4.4.2 Auto Set Pass Level
The system will recalculate the new pass level according to the 30 data and the setting here.
Select the inspection boxes and input [Standard Deviation no.], [Minimum] and [Maximum]
then press [Ok] to change the pass level.
Figure 120: Auto Pass Level Setting
[Select Item] – Select the inspection boxes to change.
[Standard Deviation no.] – Set a multiple of standard deviation to calculate
parameters. New pass level = Average Result +Standard Deviation no.* Standard
Deviation. The [Average Result] and [Standard Deviation] is calculated from 30
times results.
[Minimum, Maximum] – Give new parameter a range in order not to create an
unsuitable value. If the calculated parameter is smaller than [Min.] value the system

Test Research Inc.
68 TR7500 Series User Guide –Software v.2.9.0
will modify the parameter as [Min.] value; if the calculated parameter is bigger than
[Max.] value the system will modify the parameter as [Max.] value.
[Auto Update] – It means when the total inspection number of times is over 30, the
parameter will be calculated after every inspection.
3.4.4.3 Recover Pass Level
Press to recover the one former pass level setting.
Figure 121: Confirm Recover Pass Level Window
3.4.5 Add FOV
This is only enabled in the TRAIN dialog.
Selecting [Add FOV] will show a panel map and real time FOV image. There are
two ways to add FOV.
Click on the position where you want to add an FOV on the panel map and the
camera will move to the position to grab the image. Confirm the image then
press [Add]. If it’s multi-board module the system will create FOV to the relative
position. The existing FOV can’t be selected.
Click near a position on the panel map. Press [Prev.] or [Next] to find the FOV
you want to add. If it is a multi-board module, the system will create an FOV in
the relevant position. The existing FOV cannot be shown.
Use the
control to select the appropriate camera to add or delete and FOV.
Press [Save] to save the current image in the folder in which the project is saved.
Add FOV Steps:
1. Press [Program/Add FOV]
2. Select objective FOV then press [Add]
3. Add other FOVs
4. After you finish adding FOVs press [Program/Add FOV] again.
5. Close [Train] dialog then press [Utilities/Capture FOV Images].