TR7500_Series_Software_v29_En.pdf - 第274页
Test Research Inc. 252 TR7500 Series User Guid e –Softwa re v.2.9.0 11.6.5 Set Weighting The View Model widow shows [Set W ei g hting] is sel ect ed. Set the w eig hting for specified image. See 11.9.2.6 for more in form…

Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 251
Figure 419: Data Collection Chart 2 –Change Pass Level
11.6.2 Copy
Copy the size or position to the other components with same type.
Figure 420: Confirm Copy Size and/or Position
[Yes] – Copy the size and position to the related components on other boards in a
multi-board panel. If the inspection box is trained the setting can’t be changed.
[No] – Copy just the size to the other components.
11.6.3 Save Image
Save the FOV to the folder that the SOL file is saved in. The file name is composed by date
and time.
11.6.4 Set Fail String
Users can redefine the fail string of each inspection box. This is the same method used in
[Library].

Test Research Inc.
252 TR7500 Series User Guide –Software v.2.9.0
11.6.5 Set Weighting
The View Model widow shows [Set Weighting] is selected. Set the weighting for specified
image. See
11.9.2.6 for more information about “set weighting”.
11.6.6 Set Mask
Users can create a mask in [Void] or [Extra Blob].
11.6.7 Link Box
You can assign windows that are parents and children to link. See more about [Link] in 8.2.2
11.6.8 Unlink Box
Press [Unlink] to break the link between windows. See more about [Unlink] in 8.2.3
11.6.9 Copy Box
Copy the selected inspection box in the system.
11.6.10 Cut Box
Cut the selected inspection box.
11.6.11 Paste Box
Paste the box that was chosen with the Copy or Cut command. Select a box and press Cut
Box or Copy Box first, then press Paste Box at the target FOV. The inspection box does not
appear right away: move the mouse to the correct position and left click on the image. The
dialog box shown below will appear. After the component information is input, press OK and
then the Pasted inspection box will become visible. If there are other components within
2mm of the newly-increased component, the inspection box cannot be inserted.
Figure 421: Add Component Dialog Box

Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 253
11.6.12 Move to Left FOV
Move the selected box to the left FOV.
11.6.13 Move to Right FOV
Move the selected box to the right FOV..
11.6.14 Move All Boxes
Users may move all the inspection boxes which are under the same camera at the same
time. The [Move All Boxes] dialog will appear (see following figure). Enter a positive value in
[DX] will send the camera to move right. Enter a positive value in [DY] will move the camera
down. However, some boxes will not move if they are about to be moved out of the FOV or
are on the edge of FOV within 8 pixels.
Figure 422: Move All Boxes Dialog
11.6.15 Undelete Box
Undelete the last deleted box by clicking this function.
11.6.16 Rotate Box Side
Each mouse click rotates the pin direction 90 degrees counterclockwise.
11.6.17 Set Logic
Set the [Logic] between windows. See more about logic in 8.7.1.
11.6.18 View Logic
11.6.19 Inverse Logic
Selecting this item starts the Inverse Logic function. After selecting this function, the system
regards a box that is passing the pass level as failed and a box that is not passing the pass
level as passed.
11.6.20 Test
Set the selected inspection box as [Test Box] or [Test Component].