Test Research Inc. TR7500 Series User Guide – Software v.2.9.0 303 Figure 498 : Offline Station Dialog The [Machine] option w ill have a list of AOI machines. Users may link to any m achine by using the drop-down menu. I…

100%1 / 330
Test Research Inc.
302 TR7500 Series User Guide –Software v.2.9.0
15.4 Auto Feedback Function
15.4.1 Objective
The TR7500 will send the test results to the Offline Editor software program located on a PC.
The result can be edited and compared with [Pass Level] parameters and sent back to the
TR7500 for further inspection. This function allows use of one Offline Editor to access
multiple AOI machines.
15.4.2 Settings
15.4.2.1 Hardware
Connect the TR7500 AOI machine and the Offline Editor with a crossover cable.
Figure 497: Connect TR7500 with Offline Editor PC
15.4.2.2 Offline Editor
1. Be sure to use the same version of the TR7500 software on both the AOI system and the
PC.
2. Create a directory [AOI_Offline_Data] on the PC’s C:\ drive.
3. Select [P
ARAMETER
>
U
SER
M
ODE
>
L
INK
T
O
M
ACHINE
].
4. Select [P
ARAMETER
>
P
ANEL
>
O
FFLINE
S
TATION
] and set the directory path to the target
folder. For example, to save the offline data in the repair station, the path has to be to a
folder in the repair station PC.
Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 303
Figure 498: Offline Station Dialog
The [Machine] option will have a list of AOI machines. Users may link to any machine by
using the drop-down menu. If the connection cannot be completed, check and complete the
connection between AOI and Offline Editor in order to select another AOI machine.
15.4.2.3 TR7500 Machine
1. Refer to the figure above. Select [P
ARAMETER
>
U
SER
M
ODE
>
L
INK
T
O
O
FFLINE
S
TATION
]
2. Select [P
ARAMETER
>
P
ANEL
>
O
FFLINE
S
TATION
] and set the path link to the specified
folder. This path must link to the folder that is the same as what the offline editor is set to.
3. Input [Max Fail Board Count] and [Max Fail Image Count].
15.4.3 Operation Instructions
15.4.3.1 Result Dialog
1. Copy the testing project file and the [FOV Image] folder to the Offline Editor.
2. When the TR7500 has tested one time, the failed images and [*.pnl] file are transferred to
the [AOI_Offline_Data] folder of the Offline Editor.
3. Open the main program and load the [*.pre] file that is the same as the inspection project
on the TR7500 main machine.
4. The software will create an authorized flag called [AOI ID.run] to set a flag to the other
TR7500 machines in order to avoid jammed communication. The authorized flag will
control the connection traffic of all systems and save unsent data back to the original
machines for the next available connection to [Offline Editor].
5. Press [I
NSPECTION
>
I
NSPECT
FOV
I
MAGES
] then the system starts to inspect the saved
FOV images. If the TR7500 has sent a failed image, the system uses these failed images
in place of the saved images and inspects them. Set the search range, pass level or add
alternative images according to the inspection result.
Test Research Inc.
304 TR7500 Series User Guide –Software v.2.9.0
6. Press [Confirm PASS] or [Confirm FAIL] then this data is canceled and the next result
appears.
7. When the settings are changed at the Offline Editor, the system saves a [*.fbk] file in the
[AOI_Offline_Data] folder. When AOI is transferring data to the Offline Editor, it reviews
the [*.fbk] file at the same time and the inspection parameters are modified at the next
inspection.
15.4.3.2 Train Dialog
1. Press [Train] to enter the [Train] dialog.
2. Click on an inspection box to review the result.
3. Right click on the inspection box and select [V
IEW
>
S
HOW
D
ATA
C
OLLECTION
C
HART OF
THIS
B
OX
]. The system shows the latest 1000 data of this box.
4. Change the search range, pass level or add an alternative image in this window.