TR7500_Series_Software_v29_En.pdf - 第319页

Test Research Inc. TR7500 Series User Guide – Software v.2.9.0 297 14 S TART TO I NSPECT WARNING: Risk of e l ectric shock and mechanical injury . Only fully trained persons should be allowed to pe rform the installation…

100%1 / 330
Test Research Inc.
296 TR7500 Series User Guide –Software v.2.9.0
Figure 489: Confirm Save Conveyor Width
13.4 Width Loading
1. When opening a existing project, the system shows the dialog below asking to use the
saved width.
Figure 490: Confirm Auto-Set Conveyor Width
2. When select [Yes], the system starts to adjust the conveyor width; If there is a board on
the conveyor, remove the board first. If [No] is selected, the system does not perform any
action.
3. If no data was saved in the project before, none of the above requests will be made.
Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 297
14
S
TART TO
I
NSPECT
WARNING: Risk of electric shock and mechanical injury. Only fully trained
persons should be allowed to perform the installation process.
14.1 Power On
1. Open the upper cover and confirm that there is no foreign matter inside. Be sure the front
and back emergency stop switches are released, and the interlock is set to [ON]. Then
close the upper cover.
2. Be sure that the power cable is connected to 220V single phase power.
3. Turn on the breaker that is on the back door.
4. Turn on the power switch clockwise to start the machine.
5. Press [RESET] on the HCI to start the X-Y table.
Figure 491: Push Reset on HCI to Start X-Y Table
14.2 Open Program
1. Double click on the shortcut of the TR7500 main program.
2. Open a project file (*.pre)
Test Research Inc.
298 TR7500 Series User Guide –Software v.2.9.0
Figure 492: Click on Open File Icon, Select Project to Open
3. Press [Inspect] button to start inspecting.
Figure 493: Click Inspect Button
4. Put the PCB into the tray, then press [TEST] to let the board in.
Figure 494: Press TEST Button
14.3 Check Barcode
1. Set [P
ARAMETER
>
P
ANEL
>
B
ARCODE
>
B
ARCODE
S
ETTING
]
2. Check [P
ARAMETER
>
P
ANEL
>
B
ARCODE
>
C
HECK
B
AR
C
ODE
]