TR7500_Series_Software_v29_En.pdf - 第280页
Test Research Inc. 258 TR7500 Series User Guid e –Softwa re v.2.9.0 11.7 FOV Image Boxe s/Colors Purple – M ulti-funct ion win dow. Select a [Mi ssing/Missing Polarity] or [Lead] box and double clic k on the multi-func…

Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 257
11.6.30 Get Inspection Data
For an untest [Missing] window, users can use this function to import alternative images with
the same type as this window.
Figure 431: Get Inspection Data Dialog

Test Research Inc.
258 TR7500 Series User Guide –Software v.2.9.0
11.7 FOV Image Boxes/Colors
Purple – Multi-function window. Select a [Missing/Missing Polarity] or [Lead] box
and double click on the multi-function window. The multi-function window will be
moved to the selected window.
Orange – Untrained box.
Dark blue – Untested inspection window.
Gray – Untested component.
Red – Selected box. Double-click one box and the system will automatically select
all the inspection boxes that are linked with the selected box.
Light Blue – The inspection boxes in other FOVs.
Light Purple – [Missing/Missing Polarity] or [Lead]
Light Green – Inspection boxes except [Missing/Missing Polarity/Lead].
11.8 Mouse Function in FOV Image
Left-click mouse once on any inspection box to select the box. Clicking twice will
automatically select all the linked inspection boxes of the component.
Press and hold [Alt], and left-click the mouse twice to pick an inspection box, and all the
boxes with the same inspection method will be selected as well.

Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 259
11.9 Function Area
11.9.1 Function Frame
Click the [Train Dialog] then press [F1] to change the characters of the buttons to hot keys.
Press [F1] again and switch back.
Figure 432: Train Dialog – Press [F1] to Toggle Hot Keys