TR7500_Series_Software_v29_En.pdf - 第115页

Test Research Inc. TR7500 Series User Guide – Software v.2.9.0 93 Figure 156 : On Machine Co nfirm Windo w

100%1 / 330
Test Research Inc.
92 TR7500 Series User Guide –Software v.2.9.0
3.9 Operation Tab
Figure 155: Operation Tab Functions
3.9.1 Auto Mode
After inspection the system outputs the result and starts to inspect the next PCB directly.
3.9.2 Confirm-Pass Mode
After inspection, the system outputs the result. The next PCB will not be inspected until
operator confirm.
3.9.3 ByPass Mode
The output is always “Pass”
3.9.4 Auto-Confirm Mode
After inspection, the system outputs the result and starts to inspect the next PCB directly.
The defect map will be shown as double size: this makes it easy for an operator to confirm
the defects on the AOI machine.
3.9.5 On Machine Confirm
This function is only for [Confirm Pass Mode]. When this function is selected, there must be
an operator to confirm the PCB on the AOI Machine. The data transfer to the repair station is
confirmed and doesn’t have to be confirmed again.
Right click on defect tree and confirm the defect is Pass, Fail or No Confirm. You also can
use keyboard to select, [F8] means [Confirm Pass], [F7] means [Confirm Fail] and [F6]
means [No Confirm]. [No Confirm] means the result is the same as the result of whole board.
If you select [Pass] for whole board the result for every defect will be set as [Pass]
automatically no matter what you confirmed respectively.
Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 93
Figure 156: On Machine Confirm Window
Test Research Inc.
94 TR7500 Series User Guide –Software v.2.9.0
3.10 Utilities Tab
Figure 157: Utilities Tab