Tg0699-PM-D2 2.5 "PEC Recog" T ab 0207-001 Chapter 1 2-49 2.5 "PEC Recog" T ab • • • • • Sheet Layout When you push the "PEC Recog" tab in the "Pattern Program" edit window , the f…

100%1 / 491
Tg0699-PM-D2
0207-001 Chapter 1 2-48
2.4 "PCB Backup" Tab
*4 Vacuum Rel. Wait Time [sec]
Make the ten-key window appear and enter a value in the text
box.
The value can be changed only when "Vacuum Plate" is se-
lected in the "Chuck Stage Select" text box *1.
*5 PCB Clamp Offset
Timing [sec] : Make the tenkey window appear and
enter a value in the text box.
Position [mm] : Make the tenkey window appear and
enter a value in the text box.
Bef.Clamp Bkup Spd. : The ascending speed of the backup
table can be set in the range of 10
steps (Full Speed to 90% Down) be-
fore the P.C.B. is clamped.
Aft.Clamp Bkup Spd. : The ascending speed of the backup
table can be set in the range of 10
steps (Full Speed to 90% Down) after
the P.C.B. is clamped.
*6 PCB Stopper Offset Y [mm]
Make the ten-key window appear and enter a value in the text
box.
*7 PCB Cut Offset [mm]
Make the ten-key window appear and enter a parameter in the
text box.
Tg0699-PM-D2
2.5 "PEC Recog" Tab
0207-001 Chapter 1 2-49
2.5 "PEC Recog" Tab
Sheet Layout
When you push the "PEC Recog" tab in the "Pattern Program" edit
window, the following tab sheet appears.
Fig. 3B90 "PEC Recog" Tab Sheet
Sheet Composition
*1 P.E.C. Recog. Function
Only "2-Point Recognition" is performed.
*2 Center Recognition
Push the text box twice. The text box changes to a combo box.
Push the down arrow to open the drop-down list. Select "OFF" or
"ON" from the drop-down list.
*3 Fiducial Mark #1
Make the ten-key window appear and input the values for X
(horizontal), Y (vertical), Code, Gain (only when the automatic
gain adjustment is not used) and Level (only when the automatic
gain adjustment is not used).
*1
*2
*3
*4
*5
*6
*7
Tg0699-PM-D2
2.5 "PEC Recog" Tab
0207-001 Chapter 1 2-50
*4 Fiducial Mark #2
Make the ten-key window appear and input the values for X
(horizontal), Y (vertical), Code, Gain (only when the automatic
gain adjustment is not used) and Level (only when the automatic
gain adjustment is not used).
*5 Recog. Adjust Correct
Push the text box twice. The text box changes to a combo box.
Push the down arrow to open the drop-down list. Select "OFF" or
"ON" from the drop-down list.
*6 Recog. Adjust Point
Make the ten-key window appear and enter values (coordinates)
in the "X (horizontal)" and "Y (vertical)" text boxes.
When the [ ] button is pressed on the tool bar, the
[Extended] tool bar is indicated.
When the [RP.Cpy] button is pressed on the [Extended]
tool bar, the PCB recognition coordinate data can be
transmitted to the screen recognition coordinate data.
*7 Auto Gain Adj.
Press the text box twice to show the lower direction arrow. Then,
select "ON" or "OFF" in the drop down list. Normally, select
"ON".