2OM-1088-002.pdf - 第381页

Tg0699-PM-D2 0207-001 Chapter 3 1-60

100%1 / 491
Tg0699-PM-D2
(10) Wipe out solder paste attached inside the cleaning nozzle, on
the cleaning panel and cleaning rubber squeegee, with a cloth
soaked in alcohol.
If the cleaning rubber squeegee is worn out, replace it by new
one.
Fig. 5A92
(11) Attach the cleaning rubber squeegee, cleaning rubber squeegee
mounting plate and cleaning plate with the five cleaning rubber
squeegee set bolts and five cleaning plate set bolts.
Attach them with the cleaning rubber squeegee pressed
against flat plate
such as a ruler so that the cleaning paper surface is
contacted evenly.
Fastening Torque for Set Bolts
Bolts at the Both Ends : Approx. 10 kgf/m
Other Bolts : Approx. 15 Kgf/m
(12) Attach the cleaning nozzle with the cleaning nozzle set bolts.
13. Cleaning Unit Cleaning Procedure
0207-001 Chapter 3 1-59
Cleaning Plate
Cleaning Rubber Squeegee
Cleaning
Tg0699-PM-D2
0207-001 Chapter 3 1-60
Tg0699-PM-D2
Section 2
Consumables and Servicing Parts
This section lists up the consumables and servicing parts.
0207-001 Chapter 3 2-1