Error ID Item Description
1205000 Output Conveyor Driver alarm signal was detected.
Width Driver
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If this operation does not reset the machine to its normal condition, con-
tact our service personnel for details.
1208000 Output Conveyor Driver Over-Heat
Width Driver
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If this operation does not reset the machine to its normal condition, con-
tact our service personnel for details.
1209000 Output Conveyor Operation was incompleted, within specified time.
Width Driver
(Cause 1) The driver is malfunctioning or an error has occurred during communication
with the host CPU.
(Remedy 1) Shut down the power of the machine once and power up the machine
again. After that, perform the zeroing operation.
If this operation does not reset the machine to its normal condition, the
driver may be defective. Contact our service personnel for details.