2OM-1088-002.pdf - 第248页

Tg0699-PM-D2 2.3 Error IDs and Remedial Procedures 0207-001 Chapter 2 2-43 T able 4B41

100%1 / 491
Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-42
Table 4B40
Error ID Item Description
0711000 P.E.C. Recognition P.C.B. stopper was down.
Camera Y Interlock
(Cause 1) The P.E.C. recognition Y axis is moved during the P.C.B. stopper is moved
down.
(Cause 2) The P.C.B. stopper upper limit (BPS070) is defective.
(Remedy 1) Move up the P.C.B. stopper and re-start the operation.
(Remedy 2) Adjust the sensor position.
If this operation does not reset the machine to its normal condition, it is
required to replace the sensor with a new one. Contact our service per-
sonnel for details.
0712000 P.E.C. Recognition P.C.B. warpage protection was down.
Camera Y Interlock
(Cause 1) The P.E.C. recognition Y axis is moved during the P.C.B. warpage protec-
tion is moved down.
(Remedy 1) Move up the P.C.B. warpage protection and re-start the operation.
0713000 P.E.C. Recognition Cleaning nozzle is up.
Camera Y Interlock
(Cause 1) The cleaning nozzle lower limit sensor (BPS081) is defective.
(Cause 2) The operation timing is shifted from the normal one.
(Cause 3) The P.E.C. recognition Y axis is moved during the cleaning nozzle is moved
up. (during the manual operation)
(Remedy 1) Check how the sensor is working in "Device Check" window (submenu).
When the sensor is not working, it is required to replace the sensor with
a new one. Contact our service personnel for details.
(Remedy 2) Shut down the power of the machine once and power up the machine
again. After that, restart the operation.
When the same error still occurs, contact our service personnel for de-
tails.
(Remedy 3) Perform the zeroing operation and re-start the operation.
Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-43
Table 4B41
Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-44
Table 4B42