Tg0699-PM-D2 0509-001 Chapter 3 1-52-1 12.1 Replenishment of Cleaning Solvent (3 ) Remove the cap and the internal lid of the solvent tank. Fig. 5A83 Fig. 5A83 Fig. 5A83 Fig. 5A83 Fig. 5A83 (4 ) Replenish the solvent tan…

100%1 / 491
Tg0699-PM-D2
0509-002 Chapter 3 1-52
12.1 Replenishment of Cleaning Solvent
Use industrial alcohol as a cleaning solvent for this machine.
Refer to "2.1 Preparation for Cleaning Tools" for the kinds of
industrial alcohol.
Operation Procedure
(1) Shut down the power to the machine.
Fig. 5A81
(2) Open the safety doors on the rear side of the machine.
Fig. 5A82
12.1 Replenishment of Cleaning Solvent
ON
tripped
reset
OFF
0
push
to
trip
Industrial alcohol supply must be replenished with the power switch
of the machine being turned "OFF".
Only the person in charge of maintenance work should perform this
operation.
CAUTION
Safety Door
Safety Doo
r
Tg0699-PM-D2
0509-001 Chapter 3 1-52-1
12.1 Replenishment of Cleaning Solvent
(3) Remove the cap and the internal lid of the solvent tank.
Fig. 5A83Fig. 5A83
Fig. 5A83Fig. 5A83
Fig. 5A83
(4) Replenish the solvent tank with additional industrial alcohol,
using the replenishment container.
To avoid solvent drips, be sure to use the replenishment
container equipped with a nozzle.
If you spill solvent by mistake, clean it up with a rag as soon
as possible.
After cleaning up the spilt solvent, confirm that it has dried
completely and enough ventilation is provided. After that,
turn on the power switch of the machine.
Fig. 5A83-1Fig. 5A83-1
Fig. 5A83-1Fig. 5A83-1
Fig. 5A83-1
Cap
Internal Lid
Notice
Tg0699-PM-D2
0509-002 Chapter 3 1-53
12.1 Replenishment of Cleaning Solvent
The solvent tank must be filled up to the "MAX" line with industrial
alcohol. (Approx. 1,500 ml or less)
If you fill the tank beyond the "Max" line, alcohol will overflow and drip
out of the tank, down to the floor.
Fig. 5A83-2 Solvent Tank
(5) After the replenishment of industrial alcohol, attach the internal
lid of the solvent tank and tighten the cap securely.
If air gets into the tube running between the solvent tank and the
discharge nozzle, industrial alcohol may not come out soon.
In this case, discharge a little amount of alcohol to let the air escape,
using the [Dispense Solvent (ON-OFF)] switch on the rear operation
panel.
[Dispense Solvent] Switch
Fig. 5A83-3
Solvent
Internal Lid
Cap
Gasket
Joint
Leeway
MAX Line
Note