2OM-1088-002.pdf - 第312页

Tg0699-PM-D2 2.3 Error IDs and Remedial Procedures 0207-001 Chapter 2 2-107 T able 4B105 Error ID Item Description 2203000 V acuum Pump V acuum plate side change timeover (Cause 1) The suction changeover cylinder might b…

100%1 / 491
Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-106
Table 4B104
Error ID Item Description
2123000 Operator's Error Reference position was not identified.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Perform the teaching operation again from the beginning.
2201000 Vacuum Pump Vacuum sw was not ON, within specified time.
(Cause 1) The vacuum plate is not used.
(Cause 2) Vacuum Leakage
(Cause 3) The vacuum switch is defective.
(Remedy 1) When the vacuum plate is not used, specify the vacuum plate in the pat-
tern program.
(Remedy 2) Check for vacuum leakage between the P.C.B. and the vacuum plate.
(Remedy 3) The vacuum switch might be set incorrectly or the main body of the vacuum
switch might be defective.
Contact our service personnel for details.
2202000 Vacuum Pump Cleaning side change timeover
(Cause 1) The suction changeover cylinder might be malfunctioning or the cylinder
sensor might be defective.
(Remedy 1) Shut down the power of the machine once and power up the machine
again. After that, restart the operation.
When the same error still occurs, contact our service personnel for de-
tails.
Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-107
Table 4B105
Error ID Item Description
2203000 Vacuum Pump Vacuum plate side change timeover
(Cause 1) The suction changeover cylinder might be malfunctioning or the cylinder
sensor might be defective.
(Remedy 1) Shut down the power of the machine once and power up the machine
again. After that, restart the operation.
When the same error still occurs, contact our service personnel for de-
tails.
Tg0699-PM-D2
0207-001 Chapter 2 2-108