2OM-1088-002.pdf - 第84页

Tg0699-PM-D2 1.2.8 Auto Stop (1) Hand Cleaning Stop (PCB) Set the number of P .C.B.’s to be produced before the machine is automatically stopped for manual cleaning operation. When "00" is set, this function be…

100%1 / 491
Tg0699-PM-D2
1.2.7 Setup Data
It can be determined whether or not each unit should be set up.
The settings can be changed using the menus in the "ALL
PROD. CHG." window.
(1) All Conveyor Setup
It can be determined whether or not the L conveyor width, the
table chute conveyor width, and the R conveyor width should
be set up according to the P.C.B. dimension Y (vertical).
OFF : Each conveyor width is not set up.
ON : Each conveyor width is set up.
(2) Two Camera Auto Calib.
It can be determined whether or not the two camera automatic
calibration should be performed, using the "ALL PROD. CHG."
menu.
OFF : The machine does not perform the setup operation for
the two camera automatic calibration.
ON : The machine performs the setup operation for the two
cam-era automatic calibration.
The two camera automatic calibration function works
to automatically correct the positional coordinates of
the P.E.C. and screen recognition cameras.
(3) Screen Recog
It can be determined whether or not the screen recognition
should be performed, using the "ALL PROD. CHG." menu.
OFF : The machine does not perform any setup operation for
screen recognition.
ON : The machine performs the setup operation for screen
rec-ognition.
(4) Prntng Prs. Adj
Set whether or not the printing pressure is adjusted, using the
"Overall Setup" menu.
OFF : The printing pressure is not adjusted.
ON : The printing pressure is adjusted.
All Conveyor Setup
ON
Fig.3B51
Two Camera Auto Calib.
ON
Fig.3B52
Screen Recog
ON
Fig.3B53
0207-001 Chapter 1 2-24
1.2 Operation Data
Prntng Prs. Adj
ON
Fig.3B54
Tg0699-PM-D2
1.2.8 Auto Stop
(1) Hand Cleaning Stop (PCB)
Set the number of P.C.B.’s to be produced before the machine
is automatically stopped for manual cleaning operation.
When "00" is set, this function becomes invalid.
Unit : pieces
Data Input Range: 0 to 99
(2) Hand Cleaning Stop (CLNG.)
Set the number of cleaning operations to be performed before
the machine is automatically stopped for manual cleaning
operation.
When "00" is set, this function becomes invalid.
Unit : counts
Data Input Range: 0 to 99
(3) Solv. Empty Stop (CLNG.)
Set the number of cleaning operations to be performed before
the machine is automatically stopped to replenish solvent for
the screen frame cleaning.
When "00" is set, this function becomes invalid.
Unit : counts
Data Input Range: 0 to 99
(4) Paste Supply Interval Mode
Select a criteria based on which the machine should be auto-
matically stopped for solder paste replenishment (related to
"(5) Paste Empty Stop (PCB)").
Paste Detect : The machine stops automatically according to
the detected amount of remaining paste.
Print PCB : The machine stops automatically according to
the number of paste-printed P.C.B.’s.
(5) Paste Empty Stop (PCB)
Set the number of P.C.B.’s to be produced before the machine
is automatically stopped for solder paste replenishment.
When "000" is set, this function becomes invalid.
Unit : pieces
Data Input Range: 0 to 999
This data is valid only when the "Print PCB" is selected
in above "(4) Paste Supply Interval Mode".
Paste Supply Interval Mode
Print PCB
Fig.3B58
Paste Empty Stop (PCB)
000
Fig.3B59
Solv. Empty Stop (CLNG.)
50
Fig.3B57
Hand Cleaning Stop (CLNG.)
00
Fig.3B56
Hand Cleaning Stop (PCB)
30
Fig.3B55
0207-001 Chapter 1 2-25
1.2 Operation Data
Tg0699-PM-D2
(6) Paste Detect
Set the number of P.C.B.’s to be produced by the time when
the subsequent detection is made after the amount of remain-
ing solder paste is once detected.
When "0" is set, this function becomes invalid.
Unit : pieces
Data Input Range: 0 to 99
This parameter becomes valid only when "Paste
Detect" is selected in the "Paste Supply Interval
Mode" text box (described in (4)).
Paste Detect
00
Fig.3B60
0207-001 Chapter 1 2-26
1.2 Operation Data