2OM-1088-002.pdf - 第295页

Tg0699-PM-D2 2.3 Error IDs and Remedial Procedures 0207-001 Chapter 2 2-90 T able 4B88

100%1 / 491
Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-89
Table 4B87
Error ID Item Description
1807000
1807001 [Camera ID] exceeds the range of setting.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If the machine is not reset to its normal condition, shut down the power of
the machine once and power up the machine again. After that, re-start
the operation.
When the same error still occurs, contact our service personnel for de-
tails.
1807003 [Camera Gain] exceeds the range of setting.
1807004 [Camera Level] exceeds the range of setting.
1807011 [Mark Size D1] exceeds the range of setting.
1807012 [Mark Size D2] exceeds the range of setting.
1807014 [Mark Judge Level] exceeds the range of setting.
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
1807029 Image around fiducial mark was unstable.
1807030 Error of mark figure similitude was extensive.
1807031 Error of mark similitude or mark size was extensive.
1807032 Specified mark was not found in window of recog.monitor.
(Cause 1) The fiducial marks do not conform to the coordinates X and Y of the fiducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Refer to Error ID 1801032 for details.
Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-90
Table 4B88
Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-91
Table 4B89
Error ID Item Description
1901000 Screen
Fiducial Mark #1
1901001 Screen [Camera ID] exceeds the range of setting.
Fiducial Mark #1
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If the machine is not reset to its normal condition, shut down the power of
the machine once and power up the machine again. After that, re-start
the operation.
When the same error still occurs, contact our service personnel for de-
tails.
1901003 Screen [Camera Gain] exceeds the range of setting.
Fiducial Mark #1
1901004 Screen [Camera Level] exceeds the range of setting.
Fiducial Mark #1
1901011 Screen [Mark Size D1] exceeds the range of setting.
Fiducial Mark #1
1901012 Screen [Mark Size D2] exceeds the range of setting.
Fiducial Mark #1
1901014 Screen [Mark Judge Level] exceeds the range of setting.
Fiducial Mark #1
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.