GL541操作手册.pdf - 第120页
Use the numerical keypad to specify the sequence number of a fiducial mark sequence in the current production program. When the START button is pressed, the X-axis and the Y table move so that the specified fiducial mark…

Chapter 3 Description of Commands
Part 3
3 - 53
Version 2.0 GL-541E Operation
• Explanation
Press [SET DATA] to specify the sequence number of the fiducial mark which will be inspected.
The [TRACE] command section is used to specify the trace mode. The display at the vision
processing monitor differs depending on the combination of trace mode settings.
Press [FORM DSPLY] to display on the vision processing monitor the mark shape specified in mark
data. This command cannot be executed unless the F1 command (SET DATA) has already been
executed. When the command is executed, the message “Specify mark sequence number” displays
in the first display area. Version V2.70 or later of the vision processing software is necessary in
order to use this command.
The [DSP REAL IMG] command displays the real image obtained by the mark camera on the vision
processing monitor. When this command is selected the fiducial mark is illuminated and an image
it is obtained. This command cannot be executed unless the F1 command (SET DATA) has already
been executed. When the command is executed, the message “Specify mark sequence number”
displays in the first display area.
Press [VP. EXE.] to inspect the specified fiducial mark (sequence number). This command cannot
be executed unless the F1 command (SET DATA) has already been executed. When the command
is executed, the message “Specify mark sequence number” displays in the first display area.
Note: The previous three commands are only available after the [SET DATA] command has been
executed. If the [SET DATA] command has not been executed, a message to that extent will appear
in the first display area.
• Explanation of the Displayed Items
Pattern : F mark pattern No. (0 – 7)
B/W : F mark B/W type (white or black)
Size_a : F mark size a
Size_b : F mark size b
Size_c : F mark size c
Scan : F mark Scan range
Result
X:Offset in X-direction.
Y:Offset in Y-direction.
Error : Error code.

Use the numerical keypad to specify the sequence number of a fiducial mark sequence in the
current production program.
When the START button is pressed, the X-axis and the Y table move so that the specified fiducial
mark is under the mark camera. An image of the mark is acquired and inspected. Data describing
the fiducial mark displays on the vision processing monitor. An error occurs if there is no board on
the Y-table.
Chapter 3 Description of Commands
Part 3
3 - 54
Version 2.0 GL-541E Operation
TEST IMAGE
Sequence 2
Pattern 0
B/W White
Size_a 1.23[mm]
Size_b 1.23[mm]
Size_c 1.23[mm]
Scan 500[um]
Result X: -123[um]
Y: 123[um]
Error: 12345678
F MARK Inspecting a Fiducial Mark 522-421
FUJI
Off line
Page 522
Command path:
GL_541E Prod 0000 Sche 00000
F MARK
Sequence no.?
[SET] - [MANUAL] - [VISION] - [VISION TEST] - [F MARK] - [SET DATA]
• Explanation

SET DATA : Press to specify the sequence number.
LEVEL SET : Press to specify the block skip mark contrast.
SET SIZE : Press to specify the block skip mark size.
DSP REAL IMG : Press to display the current image at the selected camera (only for mark
cameras).
VP. EXE : Press to carry out vision processing.
RETURN : Press to return to Page 522-430.
Chapter 3 Description of Commands
Part 3
3 - 55
Version 2.0 GL-541E Operation
TEST IMAGE
Sequence 2
Pattern White
Level 128
Size_x 1.23[mm]
Size_y 1.23[mm]
Result White
Error: 12345678
B MARK Inspecting a Block Skip Mark 522-430
FUJI
Off line
Page 522
RETURNVP EXEDSP REAL IMAGESET SIZELEVEL SETSET DATA
Command path:
GL_541E Prod 0000 Sche 00000
B MARK
Ready
[SET] - [MANUAL] - [VISION] - [VISION TEST] - [B MARK]
• Action of the function keys