4 - 13 V ersion 2.0 Chapter 2 Explanation of Proper Data 9. MG4USDA User_Define_A = 0 User specified output conditions. Not used at present. 11. MG4MASA Machine_Status A Parameter to set special machine software modes. N…

Chapter 2 Explanation of Proper Data
Examples
(1) To make the red lamp illuminate if the machine stops due to an error (0000 0000
0000 1000) or the machine stops for another reason (0000 0000 0000 0001), set
Red_Light = (0000 0000 0000 1001). An easy way to convert this number to
decimal is as follows:
(1) From the [Accessories] icon group in Windows select [Calculator].
(2) Select [Scientific] from the [View] menu.
(3) Click on the “Bin” option button and input 1001.
(4) Click on the “Dec” option button to convert this number to decimal. The
result should be 9.
Input 9 as the value for the Proper data item 3. MG4REL Red_Light.
(2) To make the yellow lamp illuminate if the machine is waiting for a board (0000
0000 1000 0000) or waiting to unload a board
(0000 0000 0100 0000), set Yellow_Light = (0000 0000 1100 0000). This is 192 in
decimal.
4. MG4YEL Yellow_Light = 16420
Signal tower yellow lamp lighting conditions (16-bit binary data).
Standard setting: 0100 0000 0010 0100 (16420)
5. MG4BLL Blue_Light = 768
Signal tower blue lamp lighting conditions (16-bit binary data).
Standard setting: 0000 0011 0000 0000 (768)
6. MG4REB Red_Flash = 8
Signal tower red lamp flashing conditions (16-bit binary data).
Standard setting: 0000 0000 0000 1000 (8)
7. MG4YEB Yellow_Flash = 8210
Signal tower yellow lamp flashing conditions (16-bit binary data).
Standard setting: 0010 0000 0001 0010 (8210)
8. MG4BLB Blue_Flash = 2241
Signal tower blue lamp flashing conditions (16-bit binary data).
Standard setting: 0000 10000 1100 0001 (2241)
4 - 12
Version 2.0
GL-541E Operation
Part 4

4 - 13
Version 2.0
Chapter 2 Explanation of Proper Data
9. MG4USDA User_Define_A = 0
User specified output conditions. Not used at present.
11. MG4MASA Machine_Status A
Parameter to set special machine software modes.
Normally set to 0.
Input a decimal number after making the setting using a 16 bit binary format.
Refer to the following table for the settings. Use the calculator function in the
Windows Accessories icon group to perform this conversion.
Standard setting: 0
Mode Bit Map Hexadecimal
1000 0000 0000 0000 8000H
0100 0000 0000 0000
4000H
0010 0000 0000 0000Specify the glue valve on position in
the production program
0001 0000 0000 0000
2000H
1000H
Specify the glue valve on position in
Proper data
0000 1000 0000 0000 0800H
0000 0100 0000 0000 0400H
Clear air pressure limit 0000 0010 0000 0000
0200H
0000 0001 0000 0000 0100H
0000 0000 1000 0000
0080H
0000 0000 0100 0000 0040H
0000 0000 0010 0000 0020H
0000 0000 0001 0000 0010H
0000 0000 0000 1000 0008H
0000 0000 0000 0100
0004H
0000 0000 0000 0010 0002H
0000 0000 0000 0001 0001HDo not perform check of remaining
glue in syringe
GL-541E Operation
Part 4

Chapter 2 Explanation of Proper Data
12. MG4MASB Machine_Status_B = 0
Parameter to set special machine software modes.
Normally set to 0.
Input a decimal number after making the setting using a 16 bit binary format.
Refer to the following table for the settings. Use the calculator function in the
Windows Accessories icon group to perform this conversion.
Standard setting: 0
Mode Bit Map Hexadecimal
1000 0000 0000 0000 8000H
0100 0000 0000 0000
4000H
0010 0000 0000 0000
0001 0000 0000 0000
2000H
1000H
0000 1000 0000 0000 0800H
0000 0100 0000 0000 0400H
0000 0010 0000 0000
0200H
0000 0001 0000 0000 0100H
0000 0000 1000 0000
0080H
0000 0000 0100 0000 0040H
0000 0000 0010 0000 0020H
0000 0000 0001 0000 0010H
0000 0000 0000 1000 0008H
0000 0000 0000 0100
0004H
0000 0000 0000 0010 0002H
0000 0000 0000 0001 0001H
Using reference pin
Do not stop automatic operation
even if waiting for temperature
setting
4 - 14
Version 2.0
GL-541E Operation