Part 6 6 - 1 1 V ersion 2.0 Chapter 1 Errors Displayed by the GL-541E 1CB04004 Cause: The glue dot extends beyond the scan area. Remedy: Check that the glue dot does not extend beyond the glue dot area as a result of exc…

Chapter 1 Errors Displayed by the GL-541E
Part 6
1.2.2 Glue Check Error Codes
1CB04001
Cause: The scan area specified by the item “Scanning Area” in the mark data
file is larger than the display.
Remedy: The maximum scanning area is 8 mm. Check whether there are any errors
in the mark data file in the production program.
1CB04002
Cause: The scan area is too narrow.
Remedy: The minimum scan area is 0.2 mm. Check whether there are any errors in
the mark data file in the production program.
1CB04003
Cause: No glue could be found in the scan area.
Remedy: The minimum glue size is 0.008 mm. Check whether or not there is any
glue in the scan area. Check also that the glue color (“Mark Color”) has
been correctly specified in mark data.
Confirm that the mark displays clearly in the image. If the image is not
clear, adjust the mark camera gain and offset. (Refer to the
GL-541E Maintenance Manual for details of how to make the adjustments.
6 - 10
Version 2.0
GL-541E Operation

Part 6
6 - 11
Version 2.0
Chapter 1 Errors Displayed by the GL-541E
1CB04004
Cause: The glue dot extends beyond the scan area.
Remedy: Check that the glue dot does not extend beyond the glue dot area as a
result of excessive glue pressure or stringing. If the scan area is too
small for the glue, check the mark data file in the production
program.
0005
Cause: The glue dot is too big.
0006
Cause: The glue dot is too small.
0007 ~ 10
Cause: Currently not used.
0011
Cause: When placing twins dots, at 0 degrees and 180 degrees, one of the
dots is smaller than the other. (The diameter of the smaller dot is less
than the diameter of the larger dot minus the value set in the Proper
data item 132: Glue check limit.)
GL-541E Operation

Chapter 1 Errors Displayed by the GL-541E
Part 6
0012
Cause: Currently not used.
0013
Cause: As for 0011 but placing is at 90 degrees and 270 degrees.
6 - 12
Version 2.0