4 - 31 V ersion 2.0 274. MG4MCGA Mark_camera_gain (0 to 255) = 0 This is the degree of magnification when the video image is acquired from the mark camera. Standard setting: 0 275. MG4MCOF Mark_camera_offset (0 to 255) =…

Chapter 2 Explanation of Proper Data
264. MG4NOQZ3 Needle_offset_Q_Z3 (-3000 to 3000) [pulse] = 0
Specify the Q-coordinate needle offset for the Z3 nozzle.
Standard setting: 0
265. MG4ZUAZ1 Z_up_app_Z1 (4 to 800) [pulse] = 600
Specify the height during the ascent of the Z1 nozzle at which the nozzle position
shift signal is given to the X, Y, and Q−axes.
Standard setting: 600
266. MG4ZUAZ2 Z_up_app_Z2 (4 to 800) [pulse] = 600
Specify the height during the ascent of the Z2 nozzle at which the nozzle position
shift signal is given to the X, Y, and Q−axes.
Standard setting: 600
267. MG4ZUAZ3 Z_up_app_Z3 (4 to 800) [pulse] = 600
Specify the height during the ascent of the Z3 nozzle at which the nozzle position
shift signal is given to the X, Y, and Q−axes.
Standard setting: 600
271. MG4MCPX Mark_camera_pixel_X (0 to 4000000) [um/pulse] = 1152000
Specify the size of 1 camera pixel in the X-direction.
A unit of um/pixel is used to ensure accuracy. Therefore the data is multiplied by
65536. This data is obtained through Proper data measurement and it cannot be
changed.
Standard setting: 1152000
272. MG4MCPY Mark_camera_pixel_Y (0 to 4000000) [um/pulse] = 1228800
Specify the size of 1 camera pixel in the Y-direction.
A unit of um/pixel is used to ensure accuracy. Therefore the data is multiplied by
65536. This data is obtained through Proper data measurement and it cannot be
changed.
Standard setting: 1228800
273. MG4MCRO Mark_camera_rotation (-196608000 to 196608000) [1/1000 deg] = 0
Specify the degree of tilt in the installation angle of the camera.
A unit of 1/1000 degrees is used to ensure accuracy. Therefore the data is multiplied
by 65536. This data is obtained through Proper data measurement and it cannot be
changed.
Standard setting: 0
4 - 30
Version 2.0
GL-541E Operation
Part 4

4 - 31
Version 2.0
274. MG4MCGA Mark_camera_gain (0 to 255) = 0
This is the degree of magnification when the video image is acquired from the mark
camera.
Standard setting: 0
275. MG4MCOF Mark_camera_offset (0 to 255) = 0
This value determines the mark video signal’s zero point. This data sets the
background and the contrast.
Standard setting: 0
276. MG4GCGA Glue_camera_gain (0 to 255) = 0
Presently not used.
277. MG4GCOF Glue_camera_offset (0 to 255) = 0
Presently not used.