GL541操作手册.pdf - 第215页
Part Six Errors and Countermeasures

Chapter 4 Vision Test Mode
Part 5
4.2.2 Setting the Level
The [LEVEL SET] command is used to specify the level of the block skip mark.
When this function key is pressed, a screen displays at which the level can be
input. The level specified here is used when the mark is inspected. The initial
value is that specified in the production program.
4.2.3 Setting the Size
The [SET SIZE] function key is used to specify the size of the block skip mark.
When this function key is pressed, a screen displays at which the size can be
input. The level specified here is used when the mark is inspected. The initial
value is that specified in the production program.
4.2.4 Displaying the Actual Image
Press the [DSP REAL-IMG] function key to display an actual image of the block
skip mark on the vision processing monitor.
4.2.5 Executing the Test
Press the [VP.EXE] function key to inspect the block skip mark specified using
the [SET DATA] function key. The results of inspection display at the bottom of
the first display area.
Results Black (Mark color)
******
(First display area)
5 - 14
Version 2.0
GL-541E Operation

Part Six
Errors and Countermeasures

Part 6
6 - 1
Version 2.0
Chapter 1 Errors Displayed by the GL-541E
1. Errors Displayed by the GL-541E
1.1 Errors Displayed in the Second Display Area
There are several types of errors displayed on the machine. One type of error causes an
emergency stop, which cuts off the 200 V power supply to the machine. Another type of
error does not cause an emergency stop but interrupts automatic operation or prevents it
from being started. Yet another type of error only displays a message but does not stop
machine operation.
If an emergency stop occurs, the Y-table is stopped and the 200 V power supply to the
machine is cut off. The RESET button has to be pressed to start the machine operation
again. The message “Emergency Stop" is displayed in red at the top of the second
display area and one of the causes in the list below is displayed in yellow.
Emergency SW Pressed
Cause: The EMERGENCY STOP button has been pressed.
Remedy: After releasing the EMERGENCY STOP button press the RESET button to
start operation again.
Air Pressure Alarm
Cause: The air pressure has dropped below the preset level.
Remedy: Adjust the air pressure to the correct value and press the RESET button.
Servo Amp Alarm
Cause: A servo amplifier is not working properly.
Remedy: Check the servo axis to see if it is overloaded.
Check the servo amplifier.
Emergency Stop
GL-541E Operation