GL541操作手册.pdf - 第197页

4 - 29 V ersion 2.0 Chapter 2 Explanation of Proper Data 255. MG4GCPY Glue_check_orgn_position_Y (0 to 40000) [pulse]= 39200 Specify the Y-coordinate of the position from where the glue check and needle offset measuremen…

100%1 / 261
Chapter 2 Explanation of Proper Data
200. MG4SOZ2 Spot_on_XY_position_Z2 (0 to 10000) [0.01 mm] = 732
Specify the point before the XY-axis reaches the glue position where the Z2-axis glue
valve turns on.
Standard setting: 732
201. MG4SOZ3 Spot_on_XY_position_Z3 (0 to 10000) [0.01 mm] = 732
Specify the point before the XY-axis reaches the glue position where the Z3-axis glue
valve turns on.
Standard setting: 732
202. MG4SOQZ1 Spot_on_Q_position_Z1 (0 to 360) [degrees] = 40
Specify the point before the Q-axis reaches the glue position where the Z1-axis glue
valve turns on.
Standard setting: 40
203. MG4SOQZ2 Spot_on_Q_position_Z2 (0 to 360) [degrees] = 40
Specify the point before the Q-axis reaches the glue position where the Z2-axis glue
valve turns on.
Standard setting: 40
204. MG4SOQZ3 Spot_on_Q_position_Z3 (0 to 360) [pulse] = 40
Specify the point before the Q-axis reaches the glue position where the Z2-axis glue
valve turns on.
Standard setting: 40
Note: Depending on the Z-axis stroke and the glue type, there may be instances where
stringing occurs. In such a case,use Spot_on_XY_position_Z1, Z2, Z3 and
Spot_on_Q_position_Z1, Z2, Z3 to help prevent stringing. To make use of these
settings, set the appropriate bit in the Proper data Machine Status A. Normally
internal machine values are used.
205. MG4SOBO Spot_on_border (0 to 1000) [msec] = 0
Presently not used.
254. MG4GCPX Glue_check_orgn_position_X (0 to 65535) [pulse]= 36500
Specify the X-coordinate of the position from where the glue check and needle offset
measurement will begin.
Standard setting: 36500
4 - 28
Version 2.0
GL-541E Operation
Part 4
4 - 29
Version 2.0
Chapter 2 Explanation of Proper Data
255. MG4GCPY Glue_check_orgn_position_Y (0 to 40000) [pulse]= 39200
Specify the Y-coordinate of the position from where the glue check and needle offset
measurement will begin.
Standard setting: 39200
256. MG4NOXZ1 Needle_offset_X_Z1 (-32768 to 32767) [pulse] = 0
Specify the X-coordinate needle offset for the Z1 nozzle.
Standard setting: 0
257. MG4NOXZ2 Needle_offset_X_Z2 (-32768 to 32767) [pulse] = 0
Specify the X-coordinate needle offset for the Z2 nozzle.
Standard setting: 0
258. MG4NOXZ3 Needle_offset_X_Z3 (-32768 to 32767) [pulse] = 0
Specify the X-coordinate needle offset for the Z3 nozzle.
Standard setting: 0
259. MG4NOYZ1 Needle_offset_Y_Z1 (-32768 to 32767) [pulse] = 0
Specify the Y-coordinate needle offset for the Z1 nozzle.
Standard setting: 0
260. MG4NOYZ2 Needle_offset_Y_Z2 (-32768 to 32767) [pulse] = 0
Specify the Y-coordinate needle offset for the Z2 nozzle.
Standard setting: 0
261. MG4NOYZ3 Needle_offset_Y_Z3 (-32768 to 32767) [pulse] = 0
Specify the Y-coordinate needle offset for the Z3 nozzle.
Standard setting: 0
262. MG4NOQZ1 Needle_offset_Q_Z1 (-3000 to 3000) [pulse] = 0
Specify the Q-coordinate needle offset for the Z1 nozzle.
Standard setting: 0
263. MG4NOQZ2 Needle_offset_Q_Z2 (-3000 to 3000) [pulse] = 0
Specify the Q-coordinate needle offset for the Z2 nozzle.
Standard setting: 0
GL-541E Operation
Part 4
Chapter 2 Explanation of Proper Data
264. MG4NOQZ3 Needle_offset_Q_Z3 (-3000 to 3000) [pulse] = 0
Specify the Q-coordinate needle offset for the Z3 nozzle.
Standard setting: 0
265. MG4ZUAZ1 Z_up_app_Z1 (4 to 800) [pulse] = 600
Specify the height during the ascent of the Z1 nozzle at which the nozzle position
shift signal is given to the X, Y, and Qaxes.
Standard setting: 600
266. MG4ZUAZ2 Z_up_app_Z2 (4 to 800) [pulse] = 600
Specify the height during the ascent of the Z2 nozzle at which the nozzle position
shift signal is given to the X, Y, and Qaxes.
Standard setting: 600
267. MG4ZUAZ3 Z_up_app_Z3 (4 to 800) [pulse] = 600
Specify the height during the ascent of the Z3 nozzle at which the nozzle position
shift signal is given to the X, Y, and Qaxes.
Standard setting: 600
271. MG4MCPX Mark_camera_pixel_X (0 to 4000000) [um/pulse] = 1152000
Specify the size of 1 camera pixel in the X-direction.
A unit of um/pixel is used to ensure accuracy. Therefore the data is multiplied by
65536. This data is obtained through Proper data measurement and it cannot be
changed.
Standard setting: 1152000
272. MG4MCPY Mark_camera_pixel_Y (0 to 4000000) [um/pulse] = 1228800
Specify the size of 1 camera pixel in the Y-direction.
A unit of um/pixel is used to ensure accuracy. Therefore the data is multiplied by
65536. This data is obtained through Proper data measurement and it cannot be
changed.
Standard setting: 1228800
273. MG4MCRO Mark_camera_rotation (-196608000 to 196608000) [1/1000 deg] = 0
Specify the degree of tilt in the installation angle of the camera.
A unit of 1/1000 degrees is used to ensure accuracy. Therefore the data is multiplied
by 65536. This data is obtained through Proper data measurement and it cannot be
changed.
Standard setting: 0
4 - 30
Version 2.0
GL-541E Operation
Part 4