Chapter 2 Explanation of Proper Data
118. MG4LOP Loading_position (-300000 to 300000) [pulse] = 0
Coordinates of the board loading position.
Standard setting: 0
120. MG4Z0Z1 Z0_Z1 (-300000 to 30000) [pulse] = 0
Specify the Z-coordinate when the Z1 nozzle touches the surface of the board.
Standard setting: 0
121. MG4Z0Z2 Z0_Z2 (-300000 to 30000) [pulse] = 0
Specify the Z_coordinate when the Z2 nozzle touches the surface of the board.
Standard setting: 0
122. MG4Z0Z3 Z0_Z3 (-300000 to 30000) [pulse] = 0
Specify the Z-coordinate when the Z3 nozzle touches the surface of the board.
Standard setting: 0
123. MG4XCZ1 XC_Z1 (–300000 to 300000) [pulse] = 0
Specify the X-coordinate of the camera with respect to the center of the Z1 nozzle.
Standard setting: 0
124. MG4XCZ2 XC_Z2 (–300000 to 300000) [pulse] = 0
Specify the X-coordinate of the camera with respect to the center of the Z2 nozzle.
Standard setting: 0
125. MG4XCZ3 XC_Z3 (–300000 to 300000) [pulse] = 0
Specify the X-coordinate of the camera with respect to the center of the Z3 nozzle.
Standard setting: 0
126. MG4YCZ1 YC_Z1 (–300000 to 300000) [pulse] = 0
Specify the Y-coordinate of the camera with respect to the center of the Z1 nozzle.
Standard setting: 0
127. MG4YCZ2 YC_Z2 (–300000 to 300000) [pulse] = 0
Specify the Y-coordinate of the camera with respect to the center of the Z2 nozzle.
Standard setting: 0
GL-541E Operation
Part 4

Chapter 2 Explanation of Proper Data
128. MG4YCZ3 YC_Z3 (–300000 to 300000) [pulse] = 0
Specify the Y-coordinate of the camera with respect to the center of the Z3 nozzle.
Standard setting: 0
131. MG4GCMZ1 G_check_multi_Z1 (1 to 200) [%] = 0
Specify the feedback coefficient for the Z1 nozzle during glue feedback control.
Standard setting: 100
132. MG4GCMZ2 G_check_multi_Z2 (1 to 200) [%] = 0
Specify the feedback coefficient for the Z2 nozzle during glue feedback control.
Standard setting: 100
133. MG4GCMZ3 G_check_multi_Z3 (1 to 200) [%] = 0
Specify the feedback coefficient for the Z3 nozzle during glue feedback control.
Standard setting: 100
134. MG4GLCL3 G_check_limit (1 to 200) [%] = 0
Specify the range over which the glue feedback control is carried out.
Feedback is carried out if the dot diameter lies within the limit set by the equation;
reference data diameter x (1 ±Glue check limit / 100).
Standard setting: 30
135. MG4DEZ1 Delta_Z1 (–32768 to 32767) [pulse] = 0
Specify the offset value from the zero setting point for the Z1 nozzle’s Q axis.
Standard setting: 0
136. MG4DEZ2 Delta_Z2 (–32768 to 32767) [pulse] = 0
Specify the offset value from the zero setting point for the Z2 nozzle’s Q axis.
Standard setting: 0
137. MG4DEZ3 Delta_Z3 (–32768 to 32767) [pulse] = 0
Specify the offset value from the zero setting point for the Z3 nozzle’s Q axis.
Standard setting: 0
4 - 22
Version 2.0
GL-541E Operation
Part 4

4 - 23
Version 2.0
Chapter 2 Explanation of Proper Data
138. MG4NEZ1 Needle_Z1 0: Single 1: Twin = 1
Specify the type of needle attached to the Z1 nozzle. Used for the glue feedback
control and needle offset.
Standard setting: 1
139. MG4NEZ2 Needle_Z2 0: Single 1: Twin = 1
Specify the type of needle attached to the Z2 nozzle. Used for the glue feedback
control and needle offset.
Standard setting: 1
140. MG4NEZ3 Needle_Z3 0: Single 1: Twin = 1
Specify the type of needle attached to the Z3 nozzle. Used for the glue feedback
control and needle offset.
Standard setting: 1
141. MG4GLDZ1 Glue_area_Z1 (1 to 200) [um/%] = 100
Specify the increase in the glue dot area for the Z1 nozzle for a 1% increase in air
pressure. Used for the glue feedback control.
Standard setting: 100
142. MG4GLDZ2 Glue_area_Z2 (1 to 200) [um/%] = 100
Specify the increase in the glue dot area for the Z2 nozzle for a 1% increase in air
pressure. Used for the glue feedback control.
Standard setting: 100
143. MG4GLDZ3 Glue_area_Z3 (1 to 200) [um/%] = 100
Specify the increase in the glue dot area for the Z3 nozzle for a 1% increase in air
pressure. Used for the glue feedback control.
Standard setting: 100
GL-541E Operation
Part 4