GL541操作手册.pdf - 第184页

Chapter 2 Explanation of Proper Data 24. MG4BUI Busy_Invalid = 0 Specify whether or not the machine refers to board request signals from the next stage (when unloading a board). [0]: No: Refer to board request signals fr…

100%1 / 261
4 - 15
Version 2.0
Chapter 2 Explanation of Proper Data
13. MG4MAID Machine_ID = 0
Parameter to set special machine software modes.
Normally set to 0.
Input a decimal number after making the setting using a 16 bit binary format.
Use the calculator function in the Windows Accessories icon group to perform this
conversion.
Standard setting: 0
14. MG4PCBL PCB_Location = 0
Specify whether the reference pin is used or not used.
[0] Corner: Reference pin is not used
[1] Pin: Reference pin is used
Standard setting: 0
20. MG4LOSA Loader_ Status_A = 0
Board loader operating conditions. Not used at present.
21. MG4LOSB Loader_ Status_B = 0
Board loader operating conditions. Not used at present.
22. MG4CVT Conveyor_Type = 0
Specify the direction of board flow.
[0]: L –> R: Board flow is from left to right (standard)
[1]: R –> L: Board flow is from right to left (optional)
Standard setting: 0
23. MG4WASG Wait_Signal = 0
Specify whether the wait signal is valid or invalid.
[0]: Off: Wait signal is not valid
[1]: On:. Wait signal is valid
GL-541E Operation
Part 4
Chapter 2 Explanation of Proper Data
24. MG4BUI Busy_Invalid = 0
Specify whether or not the machine refers to board request signals from the next
stage (when unloading a board).
[0]: No: Refer to board request signals from next stage
[1]: Yes: Ignore board request signals and feed out boards when they become
available.
Standard setting: 0
25. MG4CVC Conveyor_Control = 0
Specify whether the machine is fitted with the automatic conveyor width adjustment
mechanism.
[0]: Manu: Manual conveyor adjustment
[1]: Auto: Automatic conveyor adjustment
Standard setting: 0
26. MG4CVAL Conveyor_Adj_Limit (0.05 to 1.00) [mm] = 50
Specify the tolerance for the conveyor width setting when using automatic conveyor
width adjustment
Standard setting: 50
27. MG4CVSO Conveyor_Stop_Offset (0.00 to 2.00) [mm] = 30
Specify the offset value for stopping the motor at the target position when using
automatic conveyor width adjustment.
Standard setting: 30
28. MG4CVAT Conveyor_adj_Timer (0 to 120000) [msec] = 60000
Specify the time for automatic conveyor width adjustment. If this time is exceeded, a
time-up error occurs.
Standard setting: 60000
29. MG4WMAL Width_Max_Limit (0.00 to 655.35) [mm] = 360
Specify the maximum conveyor width.
Standard setting: 360.00
30. MG4WMIL Width_Min_Limit (0.00 to 655.35) [mm] = 50
Specify the minimum conveyor width.
Standard setting: 50.00
4 - 16
Version 2.0
GL-541E Operation
Part 4
4 - 17
Version 2.0
Chapter 2 Explanation of Proper Data
40. MG4LMS LMS_Flag = 0
Specify whether the machine is HELPS-compatible or not HELPS-compatible.
[0]: Off: Non HELPS-compatible machine
[1]: On: HELPS-compatible machine
Standard setting: 0
41. MG4CELL Cell_Status = 0
Specify the cell status.
[0]: Unit Unit cell
[1]: Active Active cell
[2]: Passive Passive cell
Standard setting: 0
42. MG4CHGOM Change_Over_Mode (0 to 200) = 0
Specify the board type report for a HELPS machine.
[0]: Manual terminate
[2]: Pattern code 1 (upper surface)
[4]: Bar code 1 (upper surface)
[5]: Bar code 2 (lower surface)
[25]: Bar code (when using two bar codes; both surfaces)
Standard setting: 0
43. MG4AUTOS Auto_Start = 0
Specify whether the machine enters automatic operation without the START button
being pressed when changeover is complete on a HELPS machine.
[0]: No: After changeover is complete, the START button is enabled
[1]: Yes: After changeover is complete, the machine starts automatically
Standard setting: No
44. MG4BKPC Backup_Plate_Check = 0
Specify whether a back-up plate change request is issued.
[0]: No: No backup plate change request is issued
[1]: Yes: A backup plate change request is issued
Standard setting: No
GL-541E Operation
Part 4