2 – 3
Version 2.0
Chapter 1 Operation
Make a note of the display (Ref.data: 2500 um
2
) on the monitor.
To change Air_P_Z1 to 50% use the above [SET] -> [MANUAL] -> [GLUE]
operation. Make a note of the same data recorded above.
Calculate the following for Air_P_Z1 at 50 (%) and Ref. data: 2000 [um2].
According to the above calculation, 1% of the area (um
2
) of Z1’s application air
pressure is 50 dots. Calculate the area (um2) for 1% of Z2 and Z3’s application air
pressure and input the values arrived at in the Proper data items listed below.
141.Glue area Z1
142.Glue area Z2
143.Glue area Z3
Air_P_Z1 (60%) 2500 [um2]
Air_P_Z2 (50%) 2000 [um2]
(10%) 500 [um2]
(1%) 50 [um2]
GL-541E Operation
Chapter 1 Operation
Part 2
(11) Measure the standard values
Perform this measurement when carrying out application volume feedback control
with the glue check.
Note: There must be glue check data within the program.
Perform the following operation:
[SET] -> [STATUS] -> [GLUE CHECK] -> [G.ref.set]
The glue volumes are read for Z1, Z2 and Z3 respectively.
(12) Transmit the Proper data previously input at F4G to the machine. Then cut and
reengage the power.
Page 000
v2.10
Off line
TEST_GL Prod 00000 Sche 00000
AUTO STEP LOADER PROGRAM SET
Ready 001080403600 jog X Y Q
*
Status
G.ref.set
BOARD WAIT NEXT
STATUS
2 – 4
GL-541E Operation
Version 2.0
Part 2
2 – 5
Version 2.0
Chapter 1 Operation
(13) Change the machine glue check mode from “G.ref.set” to “G.correct” and apply
glue dots.
[SET] -> [STATUS] -> [GLUE CHECK] -> [G.correct]
The machine compares the glue area recorded in “G. ref.set” and the area (um
2
)
recorded after changing to “G.correct”. The difference is calculated and adjustment
to the desired glue volume is carried out automatically.
(14) In order for the timer to turn on and off to control the temperature inside the
machine, the main breaker must be kept on.
Page 000
v2.10
Off line
TEST_GL Prod 00000 Sche 00000
AUTO STEP LOADER PROGRAM SET
Ready 001080403600 jog X Y Q
*
Status
G.correct
BOARD WAIT NEXT
STATUS