Chapter 2 Explanation of Proper Data
178. MG4LMAZ2 Travel_limit_max_Z2 (–10000 to 10000) [pulse] = 0
Specify the maximum limit of the Z2-axis travel range.
Standard setting: 0
179. MG4LMAZ3 Travel_limit_max_Z3 (–10000 to 10000) [pulse] = 0
Specify the maximum limit of the Z3-axis travel range.
Standard setting: 0
181. MG4SDZ1 Spot_down_XY_point_Z1 (5 to 10000) [pulse] = 250
Presently not used.
182. MG4SDZ2 Spot_down_XY_point_Z2 (5 to 10000) [pulse] = 250
Presently not used.
183. MG4SDZ3 Spot_down_XY_point_Z3 (5 to 10000) [pulse] = 250
Presently not used.
184. MG4SDQZ1 Spot_down_Q_point_Z1 (5 to 10000) [pulse] = 250
Presently not used.
185. MG4SDQZ1 Spot_down_Q_point_Z2 (5 to 10000) [pulse] = 250
Presently not used.
186. MG4SDQZ3 Spot_down_Q_point_Z3 (5 to 10000) [pulse] = 250
Presently not used.
190. MG4SCTZ1 Spot_cd_timer_Z1 (0 to 1000) [msec] = 0
Specify the delay timer for the Z1-axis lower limit.
Standard setting: 0
4 - 26
Version 2.0
GL-541E Operation
Part 4
4 - 27
Version 2.0
Chapter 2 Explanation of Proper Data
191. MG4SCTZ2 Spot_cd_timer_Z2 (0 to 1000) [msec] = 0
Specify the delay timer for the Z2-axis lower limit.
Standard setting: 0
192. MG4SCTZ3 Spot_cd_timer_Z3 (0 to 1000) [msec] = 0
Sets the delay timer for the Z3-axis lower limit.
Standard setting: 0
193. MG4SUEZ1 Spot_up_end_timer_Z1 (0 to 1000) [msec] = 0
Specify the delay timer for the Z1-axis upper limit.
Standard setting: 0
194. MG4SUEZ2 Spot_up_end_timer_Z2 (0 to 1000) [msec] = 0
Sets the delay timer for the Z2-axis upper limit.
Standard setting: 0
195. MG4SUEZ3 Spot_up_end_timer_Z3 (0 to 1000) [msec] = 0
Sets the delay timer for the Z3 axis upper limit.
Standard setting: 0
196. MG4SLEZ1 Spot_low_end_height_Z1 (–500 to 500) [mm] = -20
Specify the height of the Z1-axis glue position above the board surface.
Standard setting: -20
197. MG4SLEZ2 Spot_low_end_height_Z2 (–500 to 500) [mm] = -20
Specify the height of the Z2-axis glue position above the board surface.
Standard setting: -20
198. MG4SLEZ3 Spot_low_end_height_Z3 (–500 to 500) [mm] = -20
Specify the height of the Z3-axis glue position above the board surface.
Standard setting: -20
199. MG4SOZ1 Spot_on_XY_position_Z1 (0 to 10000) [0.01 mm]= 732
Specify the point before the XY-axis reaches the glue position where the Z1-axis glue
valve turns on.
Standard setting: 732
GL-541E Operation
Part 4
Chapter 2 Explanation of Proper Data
200. MG4SOZ2 Spot_on_XY_position_Z2 (0 to 10000) [0.01 mm] = 732
Specify the point before the XY-axis reaches the glue position where the Z2-axis glue
valve turns on.
Standard setting: 732
201. MG4SOZ3 Spot_on_XY_position_Z3 (0 to 10000) [0.01 mm] = 732
Specify the point before the XY-axis reaches the glue position where the Z3-axis glue
valve turns on.
Standard setting: 732
202. MG4SOQZ1 Spot_on_Q_position_Z1 (0 to 360) [degrees] = 40
Specify the point before the Q-axis reaches the glue position where the Z1-axis glue
valve turns on.
Standard setting: 40
203. MG4SOQZ2 Spot_on_Q_position_Z2 (0 to 360) [degrees] = 40
Specify the point before the Q-axis reaches the glue position where the Z2-axis glue
valve turns on.
Standard setting: 40
204. MG4SOQZ3 Spot_on_Q_position_Z3 (0 to 360) [pulse] = 40
Specify the point before the Q-axis reaches the glue position where the Z2-axis glue
valve turns on.
Standard setting: 40
Note: Depending on the Z-axis stroke and the glue type, there may be instances where
stringing occurs. In such a case,use Spot_on_XY_position_Z1, Z2, Z3 and
Spot_on_Q_position_Z1, Z2, Z3 to help prevent stringing. To make use of these
settings, set the appropriate bit in the Proper data Machine Status A. Normally
internal machine values are used.
205. MG4SOBO Spot_on_border (0 to 1000) [msec] = 0
Presently not used.
254. MG4GCPX Glue_check_orgn_position_X (0 to 65535) [pulse]= 36500
Specify the X-coordinate of the position from where the glue check and needle offset
measurement will begin.
Standard setting: 36500
4 - 28
Version 2.0
GL-541E Operation
Part 4