2 – 5
Version 2.0
Chapter 1 Operation
(13) Change the machine glue check mode from “G.ref.set” to “G.correct” and apply
glue dots.
[SET] -> [STATUS] -> [GLUE CHECK] -> [G.correct]
The machine compares the glue area recorded in “G. ref.set” and the area (um
2
)
recorded after changing to “G.correct”. The difference is calculated and adjustment
to the desired glue volume is carried out automatically.
(14) In order for the timer to turn on and off to control the temperature inside the
machine, the main breaker must be kept on.
Page 000
v2.10
Off line
TEST_GL Prod 00000 Sche 00000
AUTO STEP LOADER PROGRAM SET
Ready 001080403600 jog X Y Q
*
Status
G.correct
BOARD WAIT NEXT
STATUS
GL-541E Operation

Chapter 1 Operation
Part 2
1.2 Adjusting the Applied Glue Volume
Two types of glue application parameters are used to regulate the applied glue volume:
one type adjusts the volume applied for all dots and the other type adjusts the volume
applied for an individual dot.
1.2.1 Changing Volume for All Dots
There are two methods available for changing the applied glue volume for all of
the dots:
• Varying the application air pressure
• Varying the application time
For both methods, press the following function keys in sequence:
[SET] -> [MANUAL] -> [GLUE] -> [G]
Press the function keys to select the air pressure feedback control value (for AirP.
Z1, Z2, Z3) or the G data feedback control value (for CG.Z1, Z2, Z3 ) with the [▲]
[▼]keys. Then input those values from the numeric keypad.
• Function Key Menu
• Display in the first display area : G
CG. Z1 100
CG. Z2 100
CG. Z3 100
AirP Z1 50
AirP Z2 50
AirP Z3 50
For details refer to Part 3, Chapter 3, Description of Commands, page 523-100,
“Setting Application Time and Air Pressure”.
Note: The CG.Z1, CG.Z2, CG.Z3 values can be changed by changing the Proper data
items 113, 114, 115 G Correction Z1, Z2, Z3 and transmitting them to the
machine.
However, the air-pressure values set manually on the machine, AirP.Z1,
AirP.Z2, AirP.Z3, take precedence over Proper data. The settings do not
change when new Proper data is transmitted. The air pressure set by the
Proper data is referred to only when the machine memory is cleared by the
reset-start operation.
RETURN
▲▼
2 – 6
GL-541E Operation
Version 2.0

Part 2
2 – 7
Version 2.0
Chapter 1 Operation
1.2.2 Changing the Applied Glue Volume for Individual Dots
Particular application times (G data) can be changed by inputting values using
the [G] and [#] keys on the numeric keypad. This input can be made at any
time except during automatic operation.
Example:
To increase the G8 data by 20%, input: G 8 # 1 2 0 [CR]
This increases the glue application time from 80 ms to 96 ms.
Table of G Data Feedback Coefficients (%)
While holding down the rapid inching key [F], press the inching axis selection
key [2].
A table of G data feedback coefficients expressed in percentage form is
displayed, as shown above.
Press the [F] and [2] keys simultaneously once more and a table of application
times (expressed in milliseconds) appears. Press [F] and [2] again to return to
the original display.
Items unchanged from the original 100% are displayed in white. Items
increased to larger than 100% are displayed in purple and those decreased to
less than 100% are displayed in cyan.
G data multiplier
G01 100 % G21 100 % G41 100 % G61 100 % G81 100 %
G02 100 % G22 100 % G42 100 % G62 100 % G82 100 %
G03 100 % G23 100 % G43 100 % G63 100 % G83 100 %
G04 100 % G24 100 % G44 100 % G64 100 % G84 100 %
G05 100 % G25 100 % G45 100 % G65 100 % G85 100 %
G06 100 % G26 100 % G46 100 % G66 100 % G86 100 %
G07 100 % G27 100 % G47 100 % G67 100 % G87 100 %
G08 100 % G28 100 % G48 100 % G68 100 % G88 100 %
G09 100 % G29 100 % G49 100 % G69 100 % G89 100 %
G10 100 % G30 100 % G50 100 % G70 100 % G90 100 %
G11 100 % G31 100 % G51 100 % G71 100 % G91 100 %
G12 100 % G32 100 % G52 100 % G72 100 % G92 100 %
G13 100 % G33 100 % G53 100 % G73 100 % G93 100 %
G14 100 % G34 100 % G54 100 % G74 100 % G94 100 %
G15 100 % G35 100 % G55 100 % G75 100 % G95 100 %
G16 100 % G36 100 % G56 100 % G76 100 % G96 100 %
G17 100 % G37 100 % G57 100 % G77 100 % G97 100 %
G18 100 % G38 100 % G58 100 % G78 100 % G98 100 %
G19 100 % G39 100 % G59 100 % G79 100 % G99 100 %
G20 100 % G40 100 % G60 100 % G80 100 %
AUTO STEP LOADER PROGRAM SET
G008 00108040360000120 WAITBOARD
GL-541E Operation