GL541操作手册.pdf - 第99页
Press this function key to toggle between pass mode (the machine simply acts as a conveyor) and production mode. When pass mode is selected, “PASS” is displayed in the first display area. Note: The production mode “PRODU…

Press this function key to toggle between the glue dot feedback mode (G. correct) and
the reference measurement mode (G. ref. set). When the production program
includes a glue check sequence, G. correct or G. ref. set is displayed in the first
display area.
G. correct : Automatic feedback control of glue application using the CCD
camera.
G. ref. set : Read reference data for automatic feedback control.
Chapter 3 Description of Commands
Part 3
3 - 32
Version 2.0 GL-541E Operation
GLUE CHECK Selecting the Glue Check Mode 513-000
FUJI
Off line
Page 513
Command path:
GL_541E Prod 0000 Sche 00000
GLUE CHECK
[SET] - [STATUS] - [GLUCHK]
• Explanation To page

Press this function key to toggle between pass mode (the machine simply acts as a
conveyor) and production mode. When pass mode is selected, “PASS” is displayed
in the first display area.
Note: The production mode “PRODUCT” is automatically set when the machine power is
turned on.
Chapter 3 Description of Commands
Part 3
3 - 33
Version 2.0 GL-541E Operation
PASS Selecting Pass Operation 514-000
FUJI
Off line
Page 514
Command path:
GL_541E Prod 0000 Sche 00000
PASS
[SET] - [STATUS] - [PASS]
• Explanation

MCS : Press to change the MCS communication mode.
LMS : This command is only displayed for HELPS-compatible machines.
Press this key to change the LMS setting.
RETURN : Press to return to page 510.
Chapter 3 Description of Commands
515-100
515-200
510-000
Part 3
3 - 34
Version 2.0 GL-541E Operation
LINE Commands Related to MCS 515-000
FUJI
Off line
PAGE 515
LMSMCS
Command path:
GL_541E Prod 0000 Sche 00000
LINE
[SET] - [STATUS] - [LINE]
• Action of the function keys To page