Chapter 1 Errors Displayed by the GL-541E Part 6 1.2 Errors Displayed in the First Display Area Empty Check Z1 Empty Check Z2 Empty Check Z3 Cause: The glue level remaining in each respective syringe is too low. Remedy: …

Part 6
6 - 7
Version 2.0
Chapter 1 Errors Displayed by the GL-541E
PLC Link Alarm
Cause: Communication with the CPU module (board loader PLC) is not possible.
Remedy: Check the connection of the signal wires linking the VME interface board
and the CPU module (board loader PLC). For details on the VME interface
board and the CPU module (board loader PLC) refer to Part 1, “GL-541E
Machine Operation”, section 1.3, “Control System”.
Loader ROM Error
Cause: The machine ROM version is older than that of the board loader PLC.
Remedy: Contact Fuji.
GL-541E Operation

Chapter 1 Errors Displayed by the GL-541E
Part 6
1.2 Errors Displayed in the First Display Area
Empty Check Z1
Empty Check Z2
Empty Check Z3
Cause: The glue level remaining in each respective syringe is too low.
Remedy: Replenish glue or replace the syringes.
Note: After the error occurs, if the START button is pressed operation resumes. However,
operation stops again after glue has been applied to one board. Enter 0000 0000 0000
0001 in Machine_Status_A in Proper data to override the glue level check.
No Production Program
Cause: No production program is specified.
Remedy: Move a production program to the machine foreground or transmit a
program from F4G.
Invalid Command
Cause: An incorrect id code has been input.
Remedy: The system prompts the user to enter the id code as a security measure to
prevent Proper data and other data essential to the correct operation of the
machine from being accidentally changed.
If this error occurs, input the same code that is set in Proper data item 1 :
ID_Code.
Input Error
Cause: A value outside the established range was input while inputting data from
the numeric keypad, or the data was input in the wrong order.
Remedy: The permissible input range differs for each command. For details, refer to
the command information in part 3.
Mark Not Readable
Cause: The vision processing camera could not successfully inspect a fiducial mark
or measure a glue check dot.
Remedy: Refer to the following error codes and take appropriate action.
6 - 8
Version 2.0
GL-541E Operation

Part 6
6 - 9
Version 2.0
Chapter 1 Errors Displayed by the GL-541E
1.2.1 Fiducial Mark Error Codes
1CB03001
Cause: The specified mark size is too small.
Remedy: The minimum mark size is 0.5 mm. Check whether an input error
has been made in the mark data file in the production program.
1CB03002
Cause: The specified mark size is too big.
Remedy: The maximum mark size is 3.5 mm. Check whether an input error
has been made in the mark data file in the production program.
1CB03004
Cause: The mark data could not be registered.
Remedy: Check whether there are any errors in the mark data file in the
production program.
1CB03010
Cause: The mark could not be found.
Remedy: Check whether there are any errors in the mark data file in the
production program.
1CB03011
Cause: The scan area specified by the item “Scanning Area” in the mark data
file is too narrow.
Remedy: The scan area should be set to 1.5 times the mark size. The maximum
setting is 8 mm.
1CB03012
Cause: The size of the inspected mark lies outside the tolerance range.
Remedy: The mark tolerance range is ±0.3 mm. Change the mark size
specified in mark data.
1CB03013
Cause: The mark shape is distorted.
Remedy: Check that there are no foreign objects on the mark itself or in the
area around the mark
1CB03014
Cause: The mark could not be found.
Remedy: Confirm that the mark displays clearly in the image. If the image is
not clear, adjust the mark camera gain and offset.
GL-541E Operation