Chapter 2 Explanation of Proper Data
128. MG4YCZ3 YC_Z3 (–300000 to 300000) [pulse] = 0
Specify the Y-coordinate of the camera with respect to the center of the Z3 nozzle.
Standard setting: 0
131. MG4GCMZ1 G_check_multi_Z1 (1 to 200) [%] = 0
Specify the feedback coefficient for the Z1 nozzle during glue feedback control.
Standard setting: 100
132. MG4GCMZ2 G_check_multi_Z2 (1 to 200) [%] = 0
Specify the feedback coefficient for the Z2 nozzle during glue feedback control.
Standard setting: 100
133. MG4GCMZ3 G_check_multi_Z3 (1 to 200) [%] = 0
Specify the feedback coefficient for the Z3 nozzle during glue feedback control.
Standard setting: 100
134. MG4GLCL3 G_check_limit (1 to 200) [%] = 0
Specify the range over which the glue feedback control is carried out.
Feedback is carried out if the dot diameter lies within the limit set by the equation;
reference data diameter x (1 ±Glue check limit / 100).
Standard setting: 30
135. MG4DEZ1 Delta_Z1 (–32768 to 32767) [pulse] = 0
Specify the offset value from the zero setting point for the Z1 nozzle’s Q axis.
Standard setting: 0
136. MG4DEZ2 Delta_Z2 (–32768 to 32767) [pulse] = 0
Specify the offset value from the zero setting point for the Z2 nozzle’s Q axis.
Standard setting: 0
137. MG4DEZ3 Delta_Z3 (–32768 to 32767) [pulse] = 0
Specify the offset value from the zero setting point for the Z3 nozzle’s Q axis.
Standard setting: 0
4 - 22
Version 2.0
GL-541E Operation
Part 4
4 - 23
Version 2.0
Chapter 2 Explanation of Proper Data
138. MG4NEZ1 Needle_Z1 0: Single 1: Twin = 1
Specify the type of needle attached to the Z1 nozzle. Used for the glue feedback
control and needle offset.
Standard setting: 1
139. MG4NEZ2 Needle_Z2 0: Single 1: Twin = 1
Specify the type of needle attached to the Z2 nozzle. Used for the glue feedback
control and needle offset.
Standard setting: 1
140. MG4NEZ3 Needle_Z3 0: Single 1: Twin = 1
Specify the type of needle attached to the Z3 nozzle. Used for the glue feedback
control and needle offset.
Standard setting: 1
141. MG4GLDZ1 Glue_area_Z1 (1 to 200) [um/%] = 100
Specify the increase in the glue dot area for the Z1 nozzle for a 1% increase in air
pressure. Used for the glue feedback control.
Standard setting: 100
142. MG4GLDZ2 Glue_area_Z2 (1 to 200) [um/%] = 100
Specify the increase in the glue dot area for the Z2 nozzle for a 1% increase in air
pressure. Used for the glue feedback control.
Standard setting: 100
143. MG4GLDZ3 Glue_area_Z3 (1 to 200) [um/%] = 100
Specify the increase in the glue dot area for the Z3 nozzle for a 1% increase in air
pressure. Used for the glue feedback control.
Standard setting: 100
GL-541E Operation
Part 4
Chapter 2 Explanation of Proper Data
144. MG4GLCDE Glue_check_delay (0 to 4999) = 0
Specifies the delay (in number of sequences) after the dummy dots are dispensed by
the glue check sequence before the camera measures the dots.
After making this setting in Proper data and transmitting the Proper data to the
machine, either transmit a production program from F4G or change the production
program at the machine in order to enable this setting.
Standard setting: 0
149. MG4MASX Max_speed_X (1 to 100) [%] = 100
Specify the maximum speed of the X-axis servomotor.
Standard setting: 100
150. MG4MASY Max_speed_Y (1 to 100) [%] = 100
Specify the maximum speed of the Y-axis servomotor.
Standard setting: 100
151. MG4MASQ Max_speed_Q (1 to 100) [%] = 100
Specify the maximum speed of the Q-axis servomotor.
Standard setting: 100
152. MG4MASZ1 Max_speed_Z1 (1 to 100) [%] = 100
Specify the maximum speed of the Z1-axis servomotor.
Standard setting: 100
153. MG4MASZ2 Max_speed_Z2 (1 to 100) [%] = 100
Specify the maximum speed of the Z2-axis servomotor.
Standard setting: 100
154. MG4MASZ3 Max_speed_Z3 (1 to 100) [%] = 100
Specify the maximum speed of the Z3-axis servomotor.
Standard setting: 100
167. MG4LMIX Travel_limit_min_X (–10000 to 10000) [pulse] = 0
Specify the minimum limit of the X-axis travel range.
Standard setting: 0
4 - 24
Version 2.0
GL-541E Operation
Part 4