Chapter 2 Explanation of Proper Data 200. MG4SOZ2 Spot_on_XY_position_Z2 (0 to 10000) [0.01 mm] = 732 Specify the point before the XY-axis reaches the glue position where the Z2-axis glue valve turns on. Standard setting…

4 - 27
Version 2.0
Chapter 2 Explanation of Proper Data
191. MG4SCTZ2 Spot_cd_timer_Z2 (0 to 1000) [msec] = 0
Specify the delay timer for the Z2-axis lower limit.
Standard setting: 0
192. MG4SCTZ3 Spot_cd_timer_Z3 (0 to 1000) [msec] = 0
Sets the delay timer for the Z3-axis lower limit.
Standard setting: 0
193. MG4SUEZ1 Spot_up_end_timer_Z1 (0 to 1000) [msec] = 0
Specify the delay timer for the Z1-axis upper limit.
Standard setting: 0
194. MG4SUEZ2 Spot_up_end_timer_Z2 (0 to 1000) [msec] = 0
Sets the delay timer for the Z2-axis upper limit.
Standard setting: 0
195. MG4SUEZ3 Spot_up_end_timer_Z3 (0 to 1000) [msec] = 0
Sets the delay timer for the Z3 axis upper limit.
Standard setting: 0
196. MG4SLEZ1 Spot_low_end_height_Z1 (–500 to 500) [mm] = -20
Specify the height of the Z1-axis glue position above the board surface.
Standard setting: -20
197. MG4SLEZ2 Spot_low_end_height_Z2 (–500 to 500) [mm] = -20
Specify the height of the Z2-axis glue position above the board surface.
Standard setting: -20
198. MG4SLEZ3 Spot_low_end_height_Z3 (–500 to 500) [mm] = -20
Specify the height of the Z3-axis glue position above the board surface.
Standard setting: -20
199. MG4SOZ1 Spot_on_XY_position_Z1 (0 to 10000) [0.01 mm]= 732
Specify the point before the XY-axis reaches the glue position where the Z1-axis glue
valve turns on.
Standard setting: 732
GL-541E Operation
Part 4

Chapter 2 Explanation of Proper Data
200. MG4SOZ2 Spot_on_XY_position_Z2 (0 to 10000) [0.01 mm] = 732
Specify the point before the XY-axis reaches the glue position where the Z2-axis glue
valve turns on.
Standard setting: 732
201. MG4SOZ3 Spot_on_XY_position_Z3 (0 to 10000) [0.01 mm] = 732
Specify the point before the XY-axis reaches the glue position where the Z3-axis glue
valve turns on.
Standard setting: 732
202. MG4SOQZ1 Spot_on_Q_position_Z1 (0 to 360) [degrees] = 40
Specify the point before the Q-axis reaches the glue position where the Z1-axis glue
valve turns on.
Standard setting: 40
203. MG4SOQZ2 Spot_on_Q_position_Z2 (0 to 360) [degrees] = 40
Specify the point before the Q-axis reaches the glue position where the Z2-axis glue
valve turns on.
Standard setting: 40
204. MG4SOQZ3 Spot_on_Q_position_Z3 (0 to 360) [pulse] = 40
Specify the point before the Q-axis reaches the glue position where the Z2-axis glue
valve turns on.
Standard setting: 40
Note: Depending on the Z-axis stroke and the glue type, there may be instances where
stringing occurs. In such a case,use Spot_on_XY_position_Z1, Z2, Z3 and
Spot_on_Q_position_Z1, Z2, Z3 to help prevent stringing. To make use of these
settings, set the appropriate bit in the Proper data Machine Status A. Normally
internal machine values are used.
205. MG4SOBO Spot_on_border (0 to 1000) [msec] = 0
Presently not used.
254. MG4GCPX Glue_check_orgn_position_X (0 to 65535) [pulse]= 36500
Specify the X-coordinate of the position from where the glue check and needle offset
measurement will begin.
Standard setting: 36500
4 - 28
Version 2.0
GL-541E Operation
Part 4

4 - 29
Version 2.0
Chapter 2 Explanation of Proper Data
255. MG4GCPY Glue_check_orgn_position_Y (0 to 40000) [pulse]= 39200
Specify the Y-coordinate of the position from where the glue check and needle offset
measurement will begin.
Standard setting: 39200
256. MG4NOXZ1 Needle_offset_X_Z1 (-32768 to 32767) [pulse] = 0
Specify the X-coordinate needle offset for the Z1 nozzle.
Standard setting: 0
257. MG4NOXZ2 Needle_offset_X_Z2 (-32768 to 32767) [pulse] = 0
Specify the X-coordinate needle offset for the Z2 nozzle.
Standard setting: 0
258. MG4NOXZ3 Needle_offset_X_Z3 (-32768 to 32767) [pulse] = 0
Specify the X-coordinate needle offset for the Z3 nozzle.
Standard setting: 0
259. MG4NOYZ1 Needle_offset_Y_Z1 (-32768 to 32767) [pulse] = 0
Specify the Y-coordinate needle offset for the Z1 nozzle.
Standard setting: 0
260. MG4NOYZ2 Needle_offset_Y_Z2 (-32768 to 32767) [pulse] = 0
Specify the Y-coordinate needle offset for the Z2 nozzle.
Standard setting: 0
261. MG4NOYZ3 Needle_offset_Y_Z3 (-32768 to 32767) [pulse] = 0
Specify the Y-coordinate needle offset for the Z3 nozzle.
Standard setting: 0
262. MG4NOQZ1 Needle_offset_Q_Z1 (-3000 to 3000) [pulse] = 0
Specify the Q-coordinate needle offset for the Z1 nozzle.
Standard setting: 0
263. MG4NOQZ2 Needle_offset_Q_Z2 (-3000 to 3000) [pulse] = 0
Specify the Q-coordinate needle offset for the Z2 nozzle.
Standard setting: 0
GL-541E Operation