Chapter 2 Explanation of Proper Data 144. MG4GLCDE Glue_check_delay (0 to 4999) = 0 Specifies the delay (in number of sequences) after the dummy dots are dispensed by the glue check sequence before the camera measures th…

4 - 23
Version 2.0
Chapter 2 Explanation of Proper Data
138. MG4NEZ1 Needle_Z1 0: Single 1: Twin = 1
Specify the type of needle attached to the Z1 nozzle. Used for the glue feedback
control and needle offset.
Standard setting: 1
139. MG4NEZ2 Needle_Z2 0: Single 1: Twin = 1
Specify the type of needle attached to the Z2 nozzle. Used for the glue feedback
control and needle offset.
Standard setting: 1
140. MG4NEZ3 Needle_Z3 0: Single 1: Twin = 1
Specify the type of needle attached to the Z3 nozzle. Used for the glue feedback
control and needle offset.
Standard setting: 1
141. MG4GLDZ1 Glue_area_Z1 (1 to 200) [um/%] = 100
Specify the increase in the glue dot area for the Z1 nozzle for a 1% increase in air
pressure. Used for the glue feedback control.
Standard setting: 100
142. MG4GLDZ2 Glue_area_Z2 (1 to 200) [um/%] = 100
Specify the increase in the glue dot area for the Z2 nozzle for a 1% increase in air
pressure. Used for the glue feedback control.
Standard setting: 100
143. MG4GLDZ3 Glue_area_Z3 (1 to 200) [um/%] = 100
Specify the increase in the glue dot area for the Z3 nozzle for a 1% increase in air
pressure. Used for the glue feedback control.
Standard setting: 100
GL-541E Operation
Part 4

Chapter 2 Explanation of Proper Data
144. MG4GLCDE Glue_check_delay (0 to 4999) = 0
Specifies the delay (in number of sequences) after the dummy dots are dispensed by
the glue check sequence before the camera measures the dots.
After making this setting in Proper data and transmitting the Proper data to the
machine, either transmit a production program from F4G or change the production
program at the machine in order to enable this setting.
Standard setting: 0
149. MG4MASX Max_speed_X (1 to 100) [%] = 100
Specify the maximum speed of the X-axis servomotor.
Standard setting: 100
150. MG4MASY Max_speed_Y (1 to 100) [%] = 100
Specify the maximum speed of the Y-axis servomotor.
Standard setting: 100
151. MG4MASQ Max_speed_Q (1 to 100) [%] = 100
Specify the maximum speed of the Q-axis servomotor.
Standard setting: 100
152. MG4MASZ1 Max_speed_Z1 (1 to 100) [%] = 100
Specify the maximum speed of the Z1-axis servomotor.
Standard setting: 100
153. MG4MASZ2 Max_speed_Z2 (1 to 100) [%] = 100
Specify the maximum speed of the Z2-axis servomotor.
Standard setting: 100
154. MG4MASZ3 Max_speed_Z3 (1 to 100) [%] = 100
Specify the maximum speed of the Z3-axis servomotor.
Standard setting: 100
167. MG4LMIX Travel_limit_min_X (–10000 to 10000) [pulse] = 0
Specify the minimum limit of the X-axis travel range.
Standard setting: 0
4 - 24
Version 2.0
GL-541E Operation
Part 4

4 - 25
Version 2.0
Chapter 2 Explanation of Proper Data
168 MG4LMIY Travel_limit_min_Y (–10000 to 10000) [pulse] = 0
Specify the minimum limit of the Y-axis travel range.
Standard setting: 0
169. MG4LMIQ Travel_limit_min_Q (–10000 to 10000) [pulse] = 0
Presently not used.
Standard setting: 0
170. MG4LMIZ1 Travel_limit_min_Z1 (–10000 to 10000) [pulse] = 0
Specify the minimum limit of the Z1-axis travel range.
Standard setting: 0
171. MG4LMIZ2 Travel_limit_min_Z2 (–10000 to 10000) [pulse] = 0
Specify the minimum limit of the Z2-axis travel range.
Standard setting: 0
172.MG4LMIZ3 Travel_limit_min_Z3 (–10000 to 10000) [pulse] = 0
Specify the minimum limit of the Z3-axis travel range.
Standard setting: 0
174. MG4LMAX Travel_limit_max_X (–10000 to 10000) [pulse] = 0
Specify the maximum limit of the X-axis travel range.
Standard setting: 0
175. MG4LMAY Travel_limit_max_Y (–10000 to 10000) [pulse] = 0
Specify the maximum limit of the Y-axis travel range.
Standard setting: 0
176. MG4LMAQ Travel_limit_max_Q (–10000 to 10000) [pulse] = 0
Presently not used.
177. MG4LMAZ1 Travel_limit_max_Z1 (–10000 to 10000) [pulse] = 0
Specify the maximum limit of the Z1-axis travel range.
Standard setting: 0