GL541操作手册.pdf - 第186页
Chapter 2 Explanation of Proper Data 45. MG4CMLS Command_Line_Status = 0 Specify the mode of transmission with the LAN [0]: RS232C: Use RS232C [1]: LAN: Use LAN Standard setting: 0 46. MG4CMLP Command_Line _Port (0 to 30…

4 - 17
Version 2.0
Chapter 2 Explanation of Proper Data
40. MG4LMS LMS_Flag = 0
Specify whether the machine is HELPS-compatible or not HELPS-compatible.
[0]: Off: Non HELPS-compatible machine
[1]: On: HELPS-compatible machine
Standard setting: 0
41. MG4CELL Cell_Status = 0
Specify the cell status.
[0]: Unit Unit cell
[1]: Active Active cell
[2]: Passive Passive cell
Standard setting: 0
42. MG4CHGOM Change_Over_Mode (0 to 200) = 0
Specify the board type report for a HELPS machine.
[0]: Manual terminate
[2]: Pattern code 1 (upper surface)
[4]: Bar code 1 (upper surface)
[5]: Bar code 2 (lower surface)
[25]: Bar code (when using two bar codes; both surfaces)
Standard setting: 0
43. MG4AUTOS Auto_Start = 0
Specify whether the machine enters automatic operation without the START button
being pressed when changeover is complete on a HELPS machine.
[0]: No: After changeover is complete, the START button is enabled
[1]: Yes: After changeover is complete, the machine starts automatically
Standard setting: No
44. MG4BKPC Backup_Plate_Check = 0
Specify whether a back-up plate change request is issued.
[0]: No: No backup plate change request is issued
[1]: Yes: A backup plate change request is issued
Standard setting: No
GL-541E Operation
Part 4

Chapter 2 Explanation of Proper Data
45. MG4CMLS Command_Line_Status = 0
Specify the mode of transmission with the LAN
[0]: RS232C: Use RS232C
[1]: LAN: Use LAN
Standard setting: 0
46. MG4CMLP Command_Line _Port (0 to 30) = 0
Specify the communication board port number when an RS-232C is used.
0: Command line is not used.
11 – 16: Port numbers 1 to 6 on the first VM1440 board
Standard setting: 0
48. MG4BUZW Buzzer_Warning = 0
Specify whether a buzzer sounds when HELPS changeover is performed.
[0]: On: Buzzer will sound
[1]: Off: Buzzer will not sound
Standard setting: 0
49. MG4PROT Process_Timer (0 to 120000) [msec]
Specify the protocol timer value.
Standard setting: 10000
Note: A setting of about 2000 ms is appropriate.
50. MG4RDT Reader Type (0 to 9) = 0
Specify the code reader type when using a code reader to identify the board types on
a HELPS machine.
[0]: Fuji standard bar-code reader
[1]: Fuji standard pattern code reader
[2]: AT&T bar-code reader
[3]: Keyence bar-code reader
Standard setting: 0
4 - 18
Version 2.0
GL-541E Operation
Part 4

4 - 19
Version 2.0
Chapter 2 Explanation of Proper Data
51. MG4CDRT Code_Reader_Type (0 to 120000) [msec] = 10000
Specify the time to read the board type code.
Standard setting: 10000
52. MG4CDRR Code_Reader_Retry (0 to 10) = 0
Specify the number of times an attempt is made to read the board type code if an
error occurs on the first attempt.
Standard setting: 0
53. MG4RD1P Reader1_Port_No. (0 to 30) = 0
Specify the communication board port number when the upper surface code reader
is being used.
0: Command line is not used
11 ~ 16: Port numbers 1 to 6 on the first VM1440 board
Standard setting: 0
54. MG4RD2P Reader2_Port_No (0 to 30) = 0
Specify the communication board port number when the lower surface code reader is
being used.
0: Command line is not used
11 ~ 16: Port numbers 1 to 6 on the first VM1440 board
Standard setting: 0
55. MG4PCBCT PCB_Code_Terminal = 0
Specify whether a code read recovery terminal is used or not.
0: Non Not used
1: Yes Used
Standard setting: 0
57. MG4CDTP Code_Terminal_Port (0 to 30) = 0
Specify the communication board port number when the code read recovery terminal
is used.
0: Command line is not used
11 ~ 16: Port numbers 1 to 6 on the first VM1440 board.
Standard setting: 0
GL-541E Operation
Part 4