Chapter 2 Explanation of Proper Data 110. MG4APRZ1 Air Pressure_Z1 (1 to 75) [%] = 50 Specify the Z1 syringe glue air pressure. Standard setting: 050 111. MG4APRZ2 Air Pressure_Z2 (1 to 75) [%] = 50 Specify the Z2 syring…

4 - 19
Version 2.0
Chapter 2 Explanation of Proper Data
51. MG4CDRT Code_Reader_Type (0 to 120000) [msec] = 10000
Specify the time to read the board type code.
Standard setting: 10000
52. MG4CDRR Code_Reader_Retry (0 to 10) = 0
Specify the number of times an attempt is made to read the board type code if an
error occurs on the first attempt.
Standard setting: 0
53. MG4RD1P Reader1_Port_No. (0 to 30) = 0
Specify the communication board port number when the upper surface code reader
is being used.
0: Command line is not used
11 ~ 16: Port numbers 1 to 6 on the first VM1440 board
Standard setting: 0
54. MG4RD2P Reader2_Port_No (0 to 30) = 0
Specify the communication board port number when the lower surface code reader is
being used.
0: Command line is not used
11 ~ 16: Port numbers 1 to 6 on the first VM1440 board
Standard setting: 0
55. MG4PCBCT PCB_Code_Terminal = 0
Specify whether a code read recovery terminal is used or not.
0: Non Not used
1: Yes Used
Standard setting: 0
57. MG4CDTP Code_Terminal_Port (0 to 30) = 0
Specify the communication board port number when the code read recovery terminal
is used.
0: Command line is not used
11 ~ 16: Port numbers 1 to 6 on the first VM1440 board.
Standard setting: 0
GL-541E Operation
Part 4

Chapter 2 Explanation of Proper Data
110. MG4APRZ1 Air Pressure_Z1 (1 to 75) [%] = 50
Specify the Z1 syringe glue air pressure.
Standard setting: 050
111. MG4APRZ2 Air Pressure_Z2 (1 to 75) [%] = 50
Specify the Z2 syringe glue air pressure.
Standard setting: 050
112. MG4APRZ3 Air Pressure_Z3 (1 to 75) [%] = 50
Specify the Z3 syringe glue air pressure.
Standard setting: 050
Note: The machine refers to the settings Air_pressure_Z1, Z2 and Z3 only when the
Proper data is transmitted to the machine following a reset-start. At other times, the
values input at the machine using the numeric keypad take priority.
113. MG4GCOZ1 G_correction_Z2 (1 to 999) [%] = 100
Specify the feedback coefficient for the Z1 nozzle during glue feedback control
Standard setting: 100
114. MG4GCOZ2 G_correction_Z2 (1 to 999) [%] = 100
Specify the feedback coefficient for the Z2 nozzle during glue feedback control.
Standard setting: 100
115. MG4GCOZ3 G_correction_Z3 (1 to 999) [%] = 100
Specify the feedback coefficient for the Z3 nozzle during glue feedback control.
Standard setting: 100
116. MG4XO XO (–300000 to 300000) [pulse] = 0
Specify the X coordinate of the camera when the center of the camera is aligned with
the reference pin.
Standard setting: 0
117. MG4YO YO (–300000 to 300000) [pulse] = 0
Specify the Y coordinate of the camera when the center of the camera is aligned with
the reference pin.
Standard setting: 0
4 - 20
Version 2.0
GL-541E Operation
Part 4

4 - 21
Version 2.0
Chapter 2 Explanation of Proper Data
118. MG4LOP Loading_position (-300000 to 300000) [pulse] = 0
Coordinates of the board loading position.
Standard setting: 0
120. MG4Z0Z1 Z0_Z1 (-300000 to 30000) [pulse] = 0
Specify the Z-coordinate when the Z1 nozzle touches the surface of the board.
Standard setting: 0
121. MG4Z0Z2 Z0_Z2 (-300000 to 30000) [pulse] = 0
Specify the Z_coordinate when the Z2 nozzle touches the surface of the board.
Standard setting: 0
122. MG4Z0Z3 Z0_Z3 (-300000 to 30000) [pulse] = 0
Specify the Z-coordinate when the Z3 nozzle touches the surface of the board.
Standard setting: 0
123. MG4XCZ1 XC_Z1 (–300000 to 300000) [pulse] = 0
Specify the X-coordinate of the camera with respect to the center of the Z1 nozzle.
Standard setting: 0
124. MG4XCZ2 XC_Z2 (–300000 to 300000) [pulse] = 0
Specify the X-coordinate of the camera with respect to the center of the Z2 nozzle.
Standard setting: 0
125. MG4XCZ3 XC_Z3 (–300000 to 300000) [pulse] = 0
Specify the X-coordinate of the camera with respect to the center of the Z3 nozzle.
Standard setting: 0
126. MG4YCZ1 YC_Z1 (–300000 to 300000) [pulse] = 0
Specify the Y-coordinate of the camera with respect to the center of the Z1 nozzle.
Standard setting: 0
127. MG4YCZ2 YC_Z2 (–300000 to 300000) [pulse] = 0
Specify the Y-coordinate of the camera with respect to the center of the Z2 nozzle.
Standard setting: 0
GL-541E Operation