GL541操作手册.pdf - 第90页
CHANGE : Press to change the production program. QTY. SET : Press to set the scheduled production quantity. QTY. CLEAR : Press to set the number of boards produced to zero on the current production program. SKIP : Press …

RETURN : Press to return to page 300-000.
• START button
When the START button is pressed, the main conveyor moves to the loading
position. When the operation is complete, the display returns to page 300-000.
Chapter 3 Description of Commands
Part 3
3 - 23
Version 2.0 GL-541E Operation
LOAD PSTN Moving the table to the loading position 330-000
FUJI
Off line
Page 330
RETURN
Command path:
GL_541E Prod 0000 Sche 00000
LOAD PSTN
Unloading
[LOADER] - [LOAD PSTN]
• Action of the function keys To page

CHANGE : Press to change the production program.
QTY. SET : Press to set the scheduled production quantity.
QTY. CLEAR : Press to set the number of boards produced to zero on the current
production program.
SKIP : Press to skip selected blocks.
RETURN : Press to return to page 000-000.
• Explanation
When this command is selected, all the programs currently stored in the machine are displayed.
Chapter 3 Description of Commands
410-000
420-000
440-000
000-000
Part 3
3 - 24
Version 2.0 GL-541E Operation
# PROGRAM NAME Sche
1 FUJI 00010
2 NEXT 00010
3" "
9 ***** *
PROGRAM Changing the Production Program 400-000
FUJI
Off line
Page 400
RETURNSKIPQTY. CLEARQTY. SET
CHANGE
Command path:
GL_541E Prod 0000 Sche 00000
Program?
[PROGRAM]
• Action of the function keys To page

RETURN : All function keys are disabled until the carriage return [CR] key is
pressed. Press the backspace [BS] key to move the cursor back to
re-enter an incorrect input. Press to return to page 000-000.
• Explanation
Using the numerical keypad, input the number of the program and press [CR].
Chapter 3 Description of Commands
000-000
Part 3
3 - 25
Version 2.0 GL-541E Operation
# PROGRAM NAME Sche
1 FUJI 00010
2 NEXT 00010
3" "
9 ***** *
CHANGE Changing the Production Program 410-000
FUJI
Off line
Page 410
RETURNSKIPQTY. CLEARQTY. SETCHANGE
Command path:
GL_541E Prod 0000 Sche 00000
CHANGE
Program no?
[PROGRAM] - [CHANGE]
• Action of the function keys To page