OK : Press to confirm the shape of the current needle. Needle inspection is performed visually by the operator. RETURN : Press to return to Page 520. Chapter 3 Description of Commands Part 3 3 - 69 V ersion 2.0 GL-541E O…

100%1 / 261
Z1 : Press to select the Z1 syringe.
Z2 : Press to select the Z2 syringe.
Z3 : Press to select the Z3 syringe.
RETURN : Press to return to Page 520.
Explanation
This command carries out compensation of the center coordinates of the needle rotational axis and
the needle tip. It also specifies which needle will perform glue application.
Chapter 3 Description of Commands
Part 3
3 - 68
Version 2.0 GL-541E Operation
NEEDLE Measuring Needle Offset 524
FUJI
Off line
Page 524
RETURNZ3Z2Z1
Command path:
GL_541E Prod 0000 Sche 00000
NEEDLE
[SET] - [MANUAL] - [NEEDLE]
Action of the function keys
OK : Press to confirm the shape of the current needle.
Needle inspection is performed visually by the operator.
RETURN : Press to return to Page 520.
Chapter 3 Description of Commands
Part 3
3 - 69
Version 2.0 GL-541E Operation
PRESENT NEEDLE
Single needle
Z1, Z2, Z3 Checking the Needle Shape
FUJI
Off line
Page 524
RETURNOK
Command path:
GL_541E Prod 0000 Sche 00000
NEEDLE
[SET] - [MANUAL] - [NEEDLE] - [Z1], [Z2], [Z3]
Action of the function keys
NOW POS : Press to start measurement from a random position.
DEFAULT POS : Press to start measurement from the position specified in
Proper data. For reverse board flow machine,
measurement starts from the left.
Note: When one of these function keys is pressed, the current G data displays.
RETURN : Press to return to Page 520.
START button
The START button is enabled after the measurement start position is specified. When the START
button is pressed, glue is dispensed in the needle center measurement area and the position of the
glue dots is inspected by the camera.
Chapter 3 Description of Commands
524-110
524-110
Part 3
3 - 70
Version 2.0 GL-541E Operation
twin Needle Real-G50
Z1 Setting Z1 Needle Offset Starting Position 524-100
FUJI
Off line
Page 524
RETURNDEFAULT POSNOW POS
Command path:
GL_541E Prod 0000 Sche 00000
Z1
[SET] - [MANUAL] - [NEEDLE] - [Z1]
Action of the function keys To page