00196457-05_UM_SX12DX12_SR706_EN.pdf - 第101页

User Manual SIPLACE SX1/SX2/DX1/DX2 3 Technical data and assemblies From software version SC.706.xx V ersion 06/2012 EN 3.2 Performance data for SIPLACE DX1/DX2 101 3.2 Performance dat a for SIPLACE DX1/DX2 3.2.1 Machine…

100%1 / 380
3 Technical data and assemblies User Manual SIPLACE SX1/SX2/DX1/DX2
3.1 Performance data for SIPLACE SX1/SX2 From software version SC.706.xx Version 06/2012 EN
100
3.1.4 Component feeding
3
Feeder locations
Component trolley with 60 tracks
Component trolley with 30 tracks
60 feeders with 8 mm
30 feeders with 8 mm
Component trolley changeover time < 1 minute
Max. component feeding
(2 component trolleys on the SIPLACE SX)
2 component trolleys with tape reel holder and
integral waste tape bins:
When using a waffle pack changer:
120 locations for feeders with 8 mm.
90 locations for feeders with 8 mm.
Feeder module types Tape feeder modules, waffle pack tray, linear vibratory feed-
ers, dip modules, application-specific OEM feeder modules
Feeding capacity
(2 component trolleys on the SIPLACE SX)
120 tape feeder modules 8 mm X
60 tape feeder modules 2x8 mm X
60 tape feeder modules 12 mm X
60 tape feeder modules Smart Feeder 12 mm X
60 tape feeder modules Smart Feeder 16 mm X
40 tape feeder modules 16 mm X
40 tape feeder modules 24 mm X
30 tape feeder modules 32 mm X
24 tape feeder modules 44 mm X
20 tape feeder modules 56 mm X
16 tape feeder modules 72 mm X
12 tape feeder modules 88 mm X
User Manual SIPLACE SX1/SX2/DX1/DX2 3 Technical data and assemblies
From software version SC.706.xx Version 06/2012 EN 3.2 Performance data for SIPLACE DX1/DX2
101
3.2 Performance data for SIPLACE DX1/DX2
3.2.1 Machine performance
3
Placement head types SIPLACE SpeedStar (C&P20)
SIPLACE 12 segment Collect&Place (C&P12)
SIPLACE TwinStar (TH)
Placement performance
The placement performance is influenced by the different head combinations and head positions, plus the con-
veyor configurations. Individual options and customized applications also influence the placement performance.
On request, SIPLACE can calculate the actual performance of your product on your machine configuration.
IPC value [components/h]
According to the vendor-neutral conditions of the IPC 9850 standard published by the Association of Connect-
ing Electronics Industries.
SIPLACE benchmark value [components/h]
The SIPLACE benchmark value is measured during the machine acceptance tests. It corresponds to the condi-
tions set out in the SIPLACE scope of service and supply.
Theoretical maximum output value [components/h]
The theoretical maximum output value is calculated from the most favorable conditions for each machine type
and setting, and corresponds to the theoretical conditions normally used in the industry.
Placement machine
SIPLACE DX2
Placement area IPC value Benchmark value Theoretical value
C&P20 / C&P20 48,000 60,000 67,750
C&P20/C&P12 31,000 43,000 53,000
C&P12/C&P12 25,500 31,000 41,000
TH/C&P12 16,500 18,500 25,000
Placement machine
SIPLACE DX1
Placement area IPC value Benchmark value Theoretical value
C&P20 24,000 30,000 33,875
C&P12 14,000 16,000 21,000
TH 5,100 5,500 6,500
3 Technical data and assemblies User Manual SIPLACE SX1/SX2/DX1/DX2
3.2 Performance data for SIPLACE DX1/DX2 From software version SC.706.xx Version 06/2012 EN
102
3.2.2 Placement data
3
Component range-
a
0.4 mm x 0.2 mm to max. 200 mm x 110 mm
Component height C&P20
C&P12
TH
4 mm
6 mm
25 mm (greater height on request)
X/Y accuracy
b
C&P20 ± 41 μm (3), ± 55 μm (4) Component camera, type 23 (6 x 6)
C&P12 ± 45 μm (3), ± 60 μm (4) Component camera, type 28 (18 x 18)
C&P12 ± 41 μm (3), ± 55 μm (4) Component camera, type 30 (18 x 18)
TH ± 36 μm (3), ± 50 μm (4) Component camera, type 36 (32 x 32)
TH ± 26 μm (3), ± 35 μm (4) Component camera, type 33 (55 x 45)
TH ± 22 μm (3), ± 30 μm (4) Component camera, type 25 (16 x 16)
Angular accuracy C&P20 ± 0.5° (3), ± 0.7° (4) Component camera, type 23 (6 x 6)
C&P12 ± 0.5° (3), ± 0.7° (4) Component camera, type 28 (18 x 18)
C&P12 ± 0.5° (3), ± 0.7° (4) Component camera, type 30 (18 x 18)
TH ± 0.05° (3), ± 0.07° (4) Component camera, type 36 (32 x 32)
TH ± 0.05° (3), ± 0.07° (4) Component camera, type 33 (55 x 45)
TH ± 0.05° (3), ± 0.07° (4) Component camera, type 25 (16 x 16)
a) Please note that the component range that can be placed is also affected by the pad geometry, the customer-specific stan-
dards, the component packaging tolerances and the component tolerances.
b) The accuracy value, measured using the vendor-neutral IPC standard.