00196457-05_UM_SX12DX12_SR706_EN.pdf - 第67页
User Manual SIPLACE SX1/SX2/DX1/DX2 2 Operational safety From software version SC.706.xx Version 06/2012 EN 2.7 Safety equipment 67 Function 2 If the protective cover is swung upwards, the power supply to the gantry axes…

2 Operational safety User Manual SIPLACE SX1/SX2/DX1/DX2
2.7 Safety equipment From software version SC.706.xx Version 06/2012 EN
66
2.7 Safety equipment
2.7.1 Protective covers
The protective hoods and covers serve as protective devices which prevent unauthorized access
to the inside of the machine.
CAUTION
Do not stand on or otherwise access the protective hoods and covers. 2
2
Fig. 2.7 - 1 Protective covers (example of SX1/SX2)
(1) Protective cover location 1
(2) Protective cover location 2
The travel range of the gantries is protected with two covers which can be opened (items 1 and 2).
(1)
(2)

User Manual SIPLACE SX1/SX2/DX1/DX2 2 Operational safety
From software version SC.706.xx Version 06/2012 EN 2.7 Safety equipment
67
Function 2
If the protective cover is swung upwards, the power supply to the gantry axes will be immediately
interrupted. The gantry axes stop moving. The message "Close cover" is displayed on the screen.
Close the protective covers and press the START button (item 1 in fig. 2.7 - 2), to continue
placement.
2
Fig. 2.7 - 2 Position of the start buttons (green) on the machine
(1) STOP button (black) on machine
(2) Start button (green) on the machine
(1)
(2)

2 Operational safety User Manual SIPLACE SX1/SX2/DX1/DX2
2.7 Safety equipment From software version SC.706.xx Version 06/2012 EN
68
2.7.2 Switches and buttons on the machine
2.7.2.1 Position of switches and buttons on the machine
2
Fig. 2.7 - 3 Position of switches and buttons - View of the PCB output side (example of SX1/SX2)
(1) Main power switch
(2) Start button (green)
(3) EMERGENCY STOP button
(4) Stop button (black)
(T) PCB transport direction
(2)
(1)
(3)