00196457-05_UM_SX12DX12_SR706_EN.pdf - 第78页
2 Operational safety User Manual SIPLACE SX1/SX2/DX1/DX2 2.7 Safety equipment From software version SC.706.xx Version 06/2012 EN 78 2 Fig. 2.7 - 9 EMERGENCY STOP loop for SIPLACE DX1/DX2 S tart button pressed No No Ye s …

User Manual SIPLACE SX1/SX2/DX1/DX2 2 Operational safety
From software version SC.706.xx Version 06/2012 EN 2.7 Safety equipment
77
2
Fig. 2.7 - 8 EMERGENCY STOP loop for SIPLACE SX1/SX2
Start button pressed
No
No
Yes
No
No
Yes
Yes
No
Yes
2
Active
SSK
a
No
Voltage
Y axis 0 V-
X axis 0 V-
Star axis 0 V-
DP axis 42 V-
Z axis (C&P, TH) 42 V-
Z axis (CPP) 0 V-
Active
PCB conveyor Yes
Lifting table No
PCB clamping No
Width adjustment No
Tape cutter No
Component trolley feeding
device Yes
2
Active
SSK
a
No
Voltage
Y axis 0 V-
X axis 0 V-
Star axis 0 V-
DP axis 40 V-
Z axis (C&P, TH) 40 V-
Z axis (CPP) 0 V-
Active
PCB conveyor No
Lifting table No
PCB clamping No
Width adjustment No
Tape cutter No
Component trolley feeding
device Yes
a) SSK protective contactor combination K3
Yes
Compressed
air min. 0.5 MPa
(5.0 bar)?
EMERGENCY STOP button
pressed?
- Protective cover open?
- Is Y axis bumper missing?
Component trolley
EMERGENCY STOP circuit
interrupted?
Is safety mode enabled on
the user interface
?
2
Active
SSK
a
Yes
Voltage
Y axis 260 V-
X axis 260 V-
Star axis 150 V-
DP axis 42 V-
Z axis (C&P, TH) 42 V-
Z axis (CPP) 150 V-
Active
PCB conveyor Yes
Lifting table Yes
PCB clamping Yes
Width adjustment Yes
Tape cutter. Yes
Component trolley feeding
device Yes

2 Operational safety User Manual SIPLACE SX1/SX2/DX1/DX2
2.7 Safety equipment From software version SC.706.xx Version 06/2012 EN
78
2
Fig. 2.7 - 9 EMERGENCY STOP loop for SIPLACE DX1/DX2
Start button pressed
No
No
Yes
No Yes
No
Yes
2
Active
SSK
a
No
Voltage
Y axis 0 V
X axis 0 V
Star axis 0 V
DP axis 42 V-
Z axis (C&P, TH) 42 V-
Active
PCB conveyor Yes
Lifting table No
PCB clamps No
Width adjustment No
Empty tape cutter No
2
Active
SSK
a
No
Voltage
Y axis 0 V
X axis 0 V
Star axis 0 V
DP axis 40 V-
Z axis (C&P, TH) 40
V-
Active
PCB conveyor No
Lifting table No
PCB clamps No
Width adjustment No
Empty tape cutter No
a) SSK protective contactor combination K3
Yes
Compressed
air min. 0.5 MPa
(5.0 bar)?
EMERGENCY STOP button
pressed?
- Protective cover open?
Is safety mode enabled on
the user interface
?
2
Active
SSK
a
Yes
Voltage
Y axis 260 V-
X axis 260 V-
Star axis 150 V-
DP axis 42 V-
Z axis (C&P, TH) 42 V-
Active
PCB conveyor Yes
Lifting table Yes
PCB clamping Yes
Width adjustment Yes
Tape cutter Yes

User Manual SIPLACE SX1/SX2/DX1/DX2 2 Operational safety
From software version SC.706.xx Version 06/2012 EN 2.7 Safety equipment
79
2.7.5 Hand guard
2.7.5.1 Hand guard at the locations
WARNING 2
The operational safety of the component trolley in the SIPLACE SX1/SX2 and of the DX table or
DX changeover table in the SIPLACE DX1/DX2 is ensured if at least every second free location
is occupied with a feeder module or hand guard (dummy feeder). When a waffle pack holder is
set up, every other free locations should again be protected again with a hand guard. In other
words, there must be no more than one free location between two adjacent feeder modules or
feeder module and waffle pack tray holder.
Fig. 2.7 - 10 Hand guard on the component trolley locations, on the DX table or DX changeover table
2
(1) Dummy feeder SIPLACE X, item no. 00141226-xx