User Manual SIPLACE SX1/SX2/DX1/DX2 2 Operational safety From software version SC.706.xx Version 06/2012 EN 2.9 Disab ling the compressed air supply and discharging the pressure 83 CAUTION 2 T o avoid losing data, assess…

2 Operational safety User Manual SIPLACE SX1/SX2/DX1/DX2
2.8 Residual voltages and discharge times in the machine From software version SC.706.xx Version 06/2012 EN
82
2.8.1 Residual voltages and discharge times after switching off the main switch
2
2.8.2 Residual voltages and discharge times after pressing the EMERGENCY
STOP button
2
Measurement point on the
fuse and distributor board
(A3)
(terminal/pin)
Voltage in
normal mode
Residual voltage if
main switch OFF or
power failure
Discharge
times
XB8a / XB8b; Pin 1 in each case 150 V- < 10 VDC < 2s
X25, Pin 1 42 V- < 10 VDC < 2s
X1A / X1B, Pin1 in each case 24 V- < 10 VDC < 2s
XB4; Pin 6 24 V- < 10 VDC < 2s
Measurement point on the
rectifier board (A7
(terminal/pin)
Voltage in
normal mode
Residual voltage if
main switch OFF or
power failure
Discharge
times
XB7a/XB7b, Pin1 in each case 260 V- < 10 VDC < 2s
At the marked point on the rec-
tifier DC40V-S 42 V- < 10 VDC < 2s
Measurement point on the
fuse and distributor board
(A3)
(terminal/pin)
Voltage in
normal mode
Residual voltage after
EMERGENCY STOP
Discharge
times
XB8a / XB8b; Pin 1 in each case 150 V- < 10 VDC < 2s
XB4; Pin 6 24 V- < 10 VDC < 2s
Measurement point on the
rectifier board (A7
(terminal/pin)
Voltage in
normal mode
Residual voltage after
EMERGENCY STOP
Discharge
times
XB7a/XB7b, Pin1 in each case 260 V- < 10 VDC < 2s
At the marked point on the rec-
tifier DC40V-S 42 V- < 10 VDC < 2s

User Manual SIPLACE SX1/SX2/DX1/DX2 2 Operational safety
From software version SC.706.xx Version 06/2012 EN 2.9 Disabling the compressed air supply and discharging the pressure
83
CAUTION 2
To avoid losing data, assess the following criteria before switching off your machine (apart from in
emergencies):
– Has the machine finished transmitting machine, setup and panel data?
– Has the machine finished processing the PCB?
– Has the machine completed the run-up phase?
2.9 Disabling the compressed air supply and discharging
the pressure
The compressed air working pressure of the machine is set to 0.50 ± 0.025 MPa (5.0 ± 0.25 bar).
The position of the compressed air unit is shown at item 1 in fig. 2.9 - 1
, page 84 ) The supply of
compressed air to the machine can be interrupted with the shutoff valve (item 2 in fig. 2.9 - 1
, page
84
).
Use the machine key to release the cover lock.
Lift the cover (see fig. 2.9 - 1, page 84 ).
Turn the lever of the shutoff valve (item 1 of fig. 2.9 - 1, page 84) from the vertical to the hor-
izontal position.
Monitor the operating pressure manometer (item 5 in fig. 2.9 - 1, page 84 ). When the machine
is switched on, the pressure discharges to 0 MPa (0 bar) within 1 minute.
CAUTION
When the machine is switched on, do not use the stop valve to interrupt the compressed air sup-
ply for more than 30 minutes. If you need to shut off the pneumatic system for longer in order to
carry out preventive maintenance or servicing work, you must switch the machine off at the main
switch and disconnect it from the power supply.

2 Operational safety User Manual SIPLACE SX1/SX2/DX1/DX2
2.9 Disabling the compressed air supply and discharging the pressure From software version SC.706.xx Version 06/2012 EN
84
2
Fig. 2.9 - 1 Compressed air unit on the machine
(1) Manometer for supply pressure of gantries 1 and 2
Target pressure: 0.46 ± 0.01 MPa, 4.6 ± 0.1 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
(2) Manometer for the machine component supply pressure
Target pressure: 0.5 ± 0.025 MPa, 4.5 ± 0.25 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
(3) Manometer for the bulkcase feeder module supply pressure
Target pressure: 0.25 ± 0.05 MPa, 2.5 ± 0.5 bar (display range: 0 - 0.6 MPa, 0 - 6 bar)
(4) Manometer for inlet pressure
Target pressure: 0.5 - 1.0 MPa, 5.0 - 10.0 bar (display range: 0 - 1.0 MPa, 0 - 10 bar)
(5) Compressed air filter
(6) Compressed air connection
(7) Stop valve in the "OPEN" position
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury. 2
(6)
(1)
(2)
(3)
(4)
(5)
(7)